Overheat/Fan Fail Led; Power Fail Led - Supermicro X7DBR-8 User Manual

Supermicro x7dbr-8 motherboards: user guide
Table of Contents

Advertisement

X7DBR-8/X7DBR-i User's Manual
Overheat/Fan Fail LED (OH)
Connect an LED to the OH/Fan Fail
connection on pins 7 and 8 of JF1 to
provide advanced warning of chassis
overheating or fan failure. Refer to
the table on the right for pin defi ni-
tions.

Power Fail LED

The Power Fail LED connection is
located on pins 5 and 6 of JF1. Re-
fer to the table on the right for pin
defi nitions.
A. OH/Fan Fail LED
B. PWR Supply Fail
GLAN1
PCI-X 100MHz ZCR
SXB-
PCI-X 100MHz
GLAN2
SCSI
CTRLR
PWR
4-pin
8-pin PWR
SMB
JPWF
PWR
OH/Fan Fail LED
SXB-
SXB-
JOH1
2-12
OH/Fan Fail LED
Pin Defi nitions (JF1)
Pin#
Defi nition
7
Vcc
8
Ground
OH/Fan Fail Indicator
Status
State
Defi nition
Off
Normal
On
Overheat
Flash-
Fan Fail
ing
PWR Fail LED
Pin Defi nitions (JF1)
Pin#
Defi nition
5
Vcc
6
Ground
20
19
Ground
X
Power LED
HDD LED
NIC1 LED
NIC2 LED
A
PWR Fail LED
B
Reset
Ground
Ground
PWR
2
1
NMI
X
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
Reset Button
Power Button

Advertisement

Table of Contents
loading

This manual is also suitable for:

X7dbr-i

Table of Contents