Wiring Plan - Version Ip66/Ip68 (1 Bar) - Vega VEGACAL 63 Operating Instructions Manual

Capacitive rod electrode for continuous level measurement
Table of Contents

Advertisement

Electronics and connec-
tion compartment
Wiring plan
Wire assignment, con-
nection cable
VEGACAL 63 • For connection to a controller
2
Fig. 9: Electronics and connection compartment - single chamber housing
1
Ground terminal for connection of the cable screening
2
Spring-loaded terminals for voltage supply
1
Fig. 10: Wiring plan - single chamber housing
1
Voltage supply/Signal output
5.4

Wiring plan - version IP66/IP68 (1 bar)

Fig. 11: Wire assignment, connection cable
1
Brown (+) and blue (-) to power supply or to the processing system
2
Shielding
5 Connecting to power supply
1
2
1
2
1
1
2