M-system R3-DS4 Instruction Manual page 2

4 - 20ma input module

Advertisement

TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
DIMENSIONS mm (inch)
CONNECTION DIAGRAM
2W-XMTR (EXC)
INPUT 1
INPUT (ISOLATOR)
2W-XMTR (EXC)
INPUT 2
INPUT (ISOLATOR)
2W-XMTR (EXC)
INPUT 3
INPUT (ISOLATOR)
2W-XMTR (EXC)
INPUT 4
INPUT (ISOLATOR)
*For dual redundant communication.
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System's sole liability, and purchaser's exclusive remedies,
under this warranty are, at M-System's option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this warranty. To
submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: info@m-system.co.jp
27.5 (1.08)
1
20–M3
11
2
SCREW
12
3
13
4
14
5
15
6
16
7
17
8
18
9
19
10
TERMINAL
20
COVER
BUS A
+
1
BUS B*
2
+
11
250Ω
INTERNAL
12
POWER
+
3
4
+
13
250Ω
14
+
6
7
+
16
250Ω
17
+
8
9
+
18
250Ω
19
109 (4.29)
• Unused Input Channels
Close across the unused input terminals with a resistor
(5kΩ, 0.5W) as shown below.
INPUT 1
1
5kΩ (0.5W)
2
Unused channels left open are equal to the input lower
than -15%, which sets a data abnormality at the PLC or
the host device.
Unused channels can be specified and set so on the PC
Configurator Software (model: R3CON) without needing to
connect resistors at the field terminals.
WIRING INSTRUCTIONS
SOLDERLESS TERMINAL mm (inch)
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solderless
terminals with insulation sleeve do not fit. Applicable wire
size: 0.3 – 0.75 mm
2
3 (.12) max.
12 (.47) max.
R3-DS4
POSITIONING
GUIDE
INPUT 2
INPUT 3
INPUT 4
3
6
8
4
7
9
4 min.
(.16)
3.2 (.13) dia.
P. 2 / 2
EM-8368 Rev.2