9
|
Electrical installation

9.1.3 Specifications of standard wiring components

9.2 To connect the electrical wiring to the outdoor unit

Installer reference guide
50
Wire type
Stranded conductor wire
with round crimp-style
terminal
Tightening torques
Item
M4 (X1M)
M4 (earth)
The earth wire between the wire retainer and the terminal must be longer than
the other wires.
Component
Power supply cable
Interconnection cable (indoor↔outdoor)
Recommended circuit breaker
Residual current device
1 Remove the switch box cover (2 screws).
c b
B
a
a Terminal
b Screw
c Flat washer
Allowed
NOT allowed
1-3
Voltage
Phase
Frequency
Wire type
Installation method
a
b
c
B
Tightening torque (N•m)
1.2
220~240 V
1~
50 Hz
3-core cable 2.5 mm
H05RN-F (60245 IEC 57)
H07RN-F (60245 IEC 66)
3-core cable 4.0 mm
H07RN-F (60245 IEC 66)
2
4-core cable 1.5 mm
and applicable for 220~240 V
H05RN-F (60245 IEC 57)
16 A
MUST comply with applicable
legislation
4P600463-4E – 2021.12
2
2
2
or 2.5 mm
2MXM40+50A
R32 Split series