1.5 Power Supply

AC 100-240 input or DC 12.6V
Out put 11.1V, 3,000mAh, Typical 200cycles (Splice & Heat)

1.6 Size and Weight

Size:124(L)mm x 123(W)mm x 138(H)mm
weight:1.1kg (with battery : 1.3kg)

1.7 Environmental Conditions

Operating conditions: Altitude: 0 to 5000m, relative humidity: 0 to 95%,
temperature: -10 to 50 ℃ , the maximum wind speed: 15m / s;
Storage conditions: relative humidity: 0 to 95%, temperature: -20 to 60 ℃ ,
battery: -20 to 30 ℃ for long-term storage

1.8 Others

Observation and display: Two cameras (orthogonally view), 4.3-inch color LCD
touch screen
Fiber Display (Magnification) : X/Y (Single image): 260x, X&Y (Dual image): 130x
Tension test:1.96 to 2.25N.
Terminals:
Port
SD card
Inside the inner device, SD card drive, program for storage
MINI USB External outside the device, data encryption function and image save
06
Descriptions

Chapter 2 Installation

2.1 Safety Warning and Precautions

As MINI3S is designed for fusion splicing silica glass optical fibers, it is very
important that the splicer should not be used for any other purposes. The splicer is
a precision instrument and must be handled with caution. Therefore, you must read
the following safety rules and general precautions in this manual regarding the use
and handling of MINI3S at any time. Any behaviors that do not follow the warnings
and cautions will break the safety standard about design, manufacture, and usage
of the fusion splicer. The users will be liable for any consequences incurred from
violation of the related requirements!

2.2 Operational Safety Warnings

① Never operate the splicer in an environment where flammable liquids or vapors
exist.
② DO NOT touch the electrodes when the splicer is on.
Note: Only use specified electrodes for the fusion splicer. Select [Replace electrode]
in maintenance menu to replace electrodes, or turn off the splicer and disconnect
the AC power source or remove battery before replacing electrodes. Discharging is
prohibited before the electrodes are placed as a pair.
③ DO NOT disassemble or modify any components of the splicer without approval,
except for the permitted-to-disassemble / modify components or parts by users
stated in this manual. Component replacement and its internal adjustment must be
implemented by authorized technicians or engineers.
④ Handle the main supply cable carefully. Pull out the cable from the electrical
socket by holding only the wall plug and not by pulling the cable. Always ensure this
cable to be in good condition. Otherwise, there is a risk of fire or electrical shock.
⑤ To prevent any fire or electrical shock, do not expose the splicer to rain or damp
conditions.
⑥ Safety glasses should always be worn during fiber preparation and splicing
operation. Fiber fragments can be extremely dangerous if they come into contact
with the eye, skin, or are ingested.
⑦ Turn off the fusion splicer immediately, and disconnect the adapter from the port
of power supply input on the splicer if user observes the following the following
faults, to avoid malfunction or beyond repair: