Optional Wall Thermostat
A wall thermostat may be installed if desired; follow
the wiring diagram below. FPI offers an optional
programmable thermostat, but any 250-750 millivolt
rated non-anticipator type thermostat that is CSA,
ULC, or UL approved may be used.
Thermostat Wire Table
Recommended Maximum Lead
Length (Two-Wire) When Using Wall
Thermostat (CP-2 System)
WIre Size
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
Do not connect the millivolt wall
thermostat wires to the 120 V
wires.
Supplied Remote Control
Use the FPI remote control kit supplied with this
unit. Use of other systems may void your warranty.
The remote control kit comes with a handheld
transmitter and a remote receiver.
Install three AAA alkaline batteries in the transmit-
ter and four AA alkaline batteries in the receiver.
Switch the remote receiver to "remote" mode - it
is now ready for operation.
The remote receiver will be located on the
lower right side of the appliance. See below.
Final Check
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:
1. Clocking the appliance to ensure the correct
firing rate (noted on the label) at 15 minutes.
2. If required, adjusting the primary air to ensure
that the flame does not carbon. Allow the unit
to burn for 15 min. to stabilize.
3. Checking for proper draft.
Max. Length
50 ft.
Any alteration to the product
32 ft.
that causes sooting or carboning
20 ft.
resulting in damage to the exterior
fascia is not the responsibility of
12 ft.
the manufacturer.
9 ft.
Remote receiver
location
installation
Gi29 Direct Vent Gas Insert |
59