Maintenance Tasks

Code
A
Check that all the equipment is present, record any deficiencies.
Visually inspect the exterior of the ADTS and its associated equipment for obvious
signs of damage, dirt and the ingress of moisture. If necessary, use mild liquid
detergent and a lint-free cloth to clean the external surfaces, see the "Safety and
Installation" guide K0554.
Inspect the pressure outlet ports for ingress of dirt and moisture, if necessary, clean
with a lint-free cloth.
B
Visually inspect the pneumatic output connectors for damage.
Inspect the small o-ring on each pneumatic output connector for cuts and any signs
of wear; replace as necessary.
Visually inspect pneumatic hoses, electrical cables for cuts, splits and damage;
replace as necessary.
C
Before use, power-up the unit as detailed in the "Safety and Installation" guide
K0554. Check the date of the last calibration and, if necessary, refer to the
manufacturer
.
Record any error messages and refer to Section Fault Codes and Error Messages.
D
Daily and before use, carry out the SST and leak check detailed in Section ADTS Leak
Check.