Sony EVI-HD1 Technical Manual page 10

Hd color video camera
Hide thumbs Also See for EVI-HD1:
Table of Contents

Advertisement

AE – Iris Priority
The iris can be set freely by the user to 18 steps
between F1.8 and Close.
The gain and shutter speed are set automatically
according to the brightness of the subject.
parameter
IRIS (F1.8) F No.
11
F1.8
10
F2.0
0F
F2.4
0E
F2.8
0D
F3.4
0C
F4.0
0B
F4.8
0A
F5.6
09
F6.8
AE – Manual
The shutter speed (21 steps), iris (18 steps) and gain (8
steps) can be set freely by the user.
AE – Bright
The bright control function adjusts both the gain and
iris using an internal algorithm according to a
brightness level freely set by the user. Exposure is
controlled by gain when dark and by iris when bright.
As both gain and iris are fixed, this mode is used when
exposing at a fixed camera sensitivity. When switching
from Full Auto or Shutter Priority Mode to Bright
Mode, the current status will be retained for a short
period of time.
Only when the AE mode is set to "Full Auto" or
"Shutter Priority," the user can switch it to "Bright."
Gain
IRIS
AGC
OPEN
MAX
AGC gain curve
CLOSE
MIN
Dark
Controlled
by gain
Bright limit controllable
for this unit
parameter
IRIS (F1.8) F No
08
F8.0
07
F9.6
06
F11
05
F14
04
F16
03
F19
02
F22
01
F26
00
CLOSE
IRIS gain curve
Bright
Controlled by IRIS
Parameter
IRIS (F1.8)
F No.
17
F1.8
16
F1.8
15
F1.8
14
F1.8
13
F1.8
12
F1.8
11
F1.8
10
F2.0
0F
F2.4
0E
F2.8
0D
F3.4
0C
F4.0
0B
F4.8
0A
F5.6
09
F6.8
08
F8.0
07
F9.6
06
F11
05
F14
04
F16
03
F19
02
F22
01
F26
00
CLOSE
When switching from the Shutter Priority mode to the
Bright mode, the shutter speed set in the Shutter
Priority mode is maintained.
Basic Functions
GAIN
18dB
15dB
12dB
9dB
6dB
3dB
0dB
0dB
0dB
0dB
0dB
0dB
0dB
0dB
0dB
0dB
0dB
0dB
0dB
0dB
0dB
0dB
0dB
0dB
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents