Replacing The Fuses - Toro TRX-20 Operator's Manual

Trencher
Hide thumbs Also See for TRX-20:
Table of Contents

Advertisement

Important: Never fill the battery with distilled
water while the battery is installed in the machine.
Electrolyte could be spilled on other parts and
cause corrosion.
2. Clean the top of the battery with a paper towel.
3. Remove the vent caps from the battery (Figure 42).
4. Slowly pour distilled water into each battery cell until
the electrolyte level is up to the Upper line (Figure 42)
on the battery case.
Important: Do not overfill the battery because
electrolyte (sulfuric acid) can cause severe
corrosion and damage to the chassis.
5. Wait five to ten minutes after filling the battery cells.
Add distilled water, if necessary, until the electrolyte
level is up to the Upper line (Figure 42) on the battery
case.
6. Install the battery vent caps.
Charging the Battery
WARNING
Charging the battery produces gasses that can
explode.
Never smoke near the battery and keep sparks and
flames away from battery.
Important: Always keep the battery fully charged
(1.265 specific gravity). This is especially important to
prevent battery damage when the temperature is below
32°F (0°C).
1. Remove the battery from the chassis; refer to Removing
the Battery (page 28).
2. Check the electrolyte level; refer to Checking the
Battery Electrolyte Level (page 29).
3. Make sure the filler caps are installed in battery.
Connect a 3 to 4 amp battery charger to the battery
posts. Charge the battery at a rate of 3 to 4 amperes
for 4 to 8 hours (12 volts). Do not overcharge the
battery.
4. When the battery is fully charged, unplug the charger
from the electrical outlet, then disconnect the charger
leads from the battery posts (Figure 43).
5. Install the battery onto the machine and connect the
battery cables, refer to Installing the Battery (page 29).
Note: Do not run the machine with the battery
disconnected, electrical damage may occur.
1. Positive Battery Post
2. Negative Battery Post

Replacing the Fuses

There are 4 fuses in the electrical system. They are under the
control panel on the left side (Figure 44).
Start Circuit
Charge Circuit
Cooler fan Circuit
Headlight (optional)
1. Fuse block
30
Figure 43
3. Red (+) Charger Lead
4. Black (-) Charger Lead
30 amp
25 amp
15 amp
15 amp