Low Battery Warning; Storage; Troubleshooting - FILL-RITE 900DB Owners Installation, Operation, And Safety Manual

Digital liquid meter
Table of Contents

Advertisement

Available languages

Available languages

IMPORTANT! When the meter is in the "Deep Sleep" mode, dispensing fluid
will NOT turn the meter on. The meter will not display or accumulate any fluid
that is dispensed while in "Deep Sleep" mode.
The last count and selected totalizer is retained and displayed when the meter is
turned on.
Pressing and releasing the TOTAL button will switch between the resettable and non-
resettable totalizers. (The R icon will be displayed when the resettable total is
displayed).
Pressing and holding the RESET button for 2 seconds will reset the counter.
Pressing and holding the RESET button and TOTAL buttons for 2 seconds will reset
the totalizer. The resettable totalizer must be active in order to reset it.
Pressing and holding the RESET button and CAL buttons for 2 seconds will display
the software version for 2 seconds and then perform a segment check for 3 seconds,
and then restore the display.
Pressing and holding the CAL button for 5 seconds will place the meter into a deep
sleep mode. Pressing any button twice will bring the meter out of deep sleep mode.
IMPORTANT! "Deep Sleep" mode is designed to maintain a status of
operational readiness while offering battery conservation. The meter should
be placed in this mode when:
Flushing the unit so the dispensed volume is not counted.
Traveling over rough surfaces (off-road) where fluid is being jostled and
you don't want volume from the motion to be counted.
Extending battery life; there is no penalty for repeatedly placing it in deep
sleep.
After 30 seconds of inactivity, the display will blank to conserve battery power.
If the meter is connected to the external power source, the display will not blank
unless forced into deep sleep mode.
If external power is removed, the meter will revert to battery only operating
characteristics and vice-versa.
The counter and totalizer 2 can be reset even if fluid flow is detected. The meter will
continue counting during the 2 second RESET button press, then reset to 0, then
resume counting.

Low Battery Warning

The digital display includes a "Low Battery"
warning indicator. When the battery reaches a
level low enough to require replacement, the
display will show "BAT" as a reminder to change
the battery. When necessary, replace batteries
per procedure on page 7.

Storage

If your meter is to be stored for a period of time, clean it thoroughly. This will help protect
the meter from possible damage.

Troubleshooting

The following troubleshooting guide is designed to help you with basic digital diagnostics
and repairs if you should encounter abnormal service from your 900 series meter. We
recommend you use only genuine Fill-Rite parts. These parts, and additional service
information is available through your authorized Fill-Rite dealer.
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

900 series900db1.5900dbbspt900db1.5bspt

Table of Contents