1.5% CO 500,000cf
TWA (OSHA Method)
Based on the CO production rates shown above the TWA would be exceeded in a 100 x 500 x 10 foot
(empty) space after 6 hours with 2 air changes per hour. (Assumes no additional CO exposure during any 8 hour
time period),
The Graph above depicts the relationships of air exchange to time and CO ppm with cubic feet area and percent
CO emissions remaining constant.
1.5% CO 750,000cf
TWA (OSHA Method)
Based on the CO production rates shown above the TWA would not be exceeded in a 100 x 750 x 10 foot (empty)
space after 8 hours with 2 air changes per hour. (Assumes no additional CO exposure during 8 hour time period)
The Graph above depicts the relationships of air exchange to time and CO ppm with cubic feet area and percent
CO emissions remaining constant.
Parts and Instruction Manual - Mirage 27" Propane Burnisher
8 Hour Time Weighted Average (OSHA Method)
Hours of Operation
1
2
0 Change/hr
17
51
1/2 Change/hr
14
35
1 Change/hr
11
26
2 change/hr
7
16
8 Hour Time Weighted Average (OSHA Method)
Hours of Operation
1
2
0 Change/hr
5
14
1/2 Change/hr
4
9
1 Change/hr
3
7
2 change/hr
2
4
3
4
5
6
103
171
257
380
62
92
123
156
42
59
76
93
24
33
42
50
3
4
5
6
27
46
69
96
16
24
33
42
11
16
20
25
7
9
11
13
7
8
479
616
189
223
110
127
59
67
7
8
128
154
50
59
29
34
16
18