Enabling Nvme Raid - Supermicro SuperWorkstation 740P-TR User Manual

Table of Contents

Advertisement

Enabling NVMe RAID

RAID for NVMe SSDs must be enabled through the UEFI BIOS.
1. Install the patch as described in the Restrictions and Requirements section on a
previous page.
2. Reboot the server.
3. Press [DEL] key to enter BIOS.
4. Switch to Advanced > Chipset Configuration > North Bridge > IIO Configuration >
Intel® VMD Technology > CPU1 & CPU2.
5. Enable the VMD according to the following rules.
For U.2 NVMe, enable all the sub-items under each PStack, based on the your model
server:
Model
740P-TR/TRT
For M.2 NVMe or NVMe AIC, enable the VMD according to which AOC card/slot it used.
Examples for some U.2 configurations follow.
6. Press [F4] to save the configuration and reboot the system.
7. Press [DEL] to enter BIOS.
8. Switch to Advanced > Intel(R) Virtual RAID on CPU > All Intel VMD Controllers >
Create RAID Volume.
9. Set Name.
10. Set RAID Level.
11. If cross-controller RAID is required, select Enable RAID spanned over VMD Controller
as shown in Figure 6-7.
12. Select specific disks for RAID with an [X].
RAID0: Select at least two [2 - 24] disks
VMD BIOS Settings
CPU1
Figure 6-6. BIOS VMD Settings
92
Chapter 6: Optional Components
CPU2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Superworkstation 740p-trt