CONTENTS CLEANING & MAINTENANCE GENERAL INFORMATION Commissioning Symbols Care and Cleaning Stop Think Act Daily Checks Staff Training Six Monthly Maintenance Electrical Connections Replacing Fan Motor and Blades Refrigerants Replacing Door and Door Hinge Case Ventilation DECOMMISSIONING & DISPOSAL PRE-INSTALLATION Decommissioning Case Service Dimensions Disposal...
PPE GEAR: NO SIT: Remember to wear Do not sit on top or on any Personal Protective Equipment whilst parts of the case. Case damages or installing the case. personal injuries may occur. PAGE 3 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Page 4
Electric shock or fire may or extension cords. Be sure to use occur if not correctly processed. a private line or socket as the main power source. Failure to do so could result in electric shock or fire. PAGE 4 PSM15E3R SEMI-VERTICAL - HUSSMANN...
If you would like to suggest material will become combustible when mixed with air that information is to be added to this manual, please under pressure and exposed to strong ignition sources. contact Hussmann directly at any time. PAGE 5 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Page 6
Contact with liquid can cause frostbite and severe damage to the eyes. The system including the refrigerant is under pressure, it should be protected from sunlight and other heat sources. PAGE 6 PSM15E3R SEMI-VERTICAL - HUSSMANN...
NO OBJECTS ON CASE: Do not place objects, stack or use the top of the case as storage. Object may fall FIGURE 1B and cause injury to personnel and/or damage to the case. PAGE 7 PSM15E3R SEMI-VERTICAL - HUSSMANN...
PRE INSTALLATION CASE DIMENSIONS AND SERVICES EXAMPLE PSM15E3R FIGURE 2A - EXAMPLE ONLY NOTE: This information is a reference only. Always refer to the latest Product Engineering Data sheet (PED). PAGE 8 PSM15E3R SEMI-VERTICAL - HUSSMANN...
60% RH, and cross draft of maximum 0.2m/s. For insure adequate loading strategies are implemented to best performance, we recommend maintaining store insure the safe transportation of the Hussmann cases. temperature below +24 C at 50% RH. Cases should be strapped using the indicated strapping points highlighted on the case packaging with the “strap...
Before storing the cabinets, ensure packaging is damaged trims, product fences, etc. If required, unbroken and does not display defects that may notify Hussmann or representative within seven (7) compromise preservation of the cabinets. days of delivery. Avoid UV rays:...
Packaging Tag (rear) Rating Plate FIGURE 2C NOTE: Refer to rating plate to identify the exact case model. The serial number and build date are key for aquiring information regarding spare parts, warranty, short parts, etc. PAGE 11 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Page 12
This is measured in Volts (V). • Fans Current: The fans flow of electricity which results from the ordered directional movement of electrically charged particles, measured in Amps (A). PAGE 12 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Merchandisers must be installed level to ensure proper operation of the refrigeration system and to FIGURE 3B - Levelling Feet ensure proper drainage of defrost water. When leveling merchandisers, use a carpenter’s level as shown below. PAGE 13 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Page 14
NOTE: All feet need to be loaded evenly on the ground. If this is not undertaken this could cause the chassis to twist. FIGURE 3D - Lining Up Case PAGE 14 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Page 15
If feet are not adjusted and levelled correctly, the case chassis could twist causing saw toothing of the doors and other misalignments. Front support feet help with the added weight of the door assembly, ensure these are adjusted correctly. PAGE 15 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Figure 3I in a clockwise direction. section 4.6, can help assist in realigning the doors. Tensioning Screw FIGURE 3I DOOR DOOR Misaligned/Not Parallel/Twisted FIGURE 3G DOOR DOOR Aligned/Parallel/Not Twisted FIGURE 3H PAGE 16 PSM15E3R SEMI-VERTICAL - HUSSMANN...
If lights appear faulty or not functioning, contact your nearest service provider for replacement. NOTE: For any information regarding customer specific lights, reach out to Hussmann. PAGE 17 PSM15E3R SEMI-VERTICAL - HUSSMANN...
The quantity and location of shelving FIGURE 3N may affect cabinet performance. Refer to PED sheet and/or your refrigeration Shelf Bracket service provider. PAGE 18 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Foam Tape (Already Fitted) possible. 3. Insert the joining bolts (found in the blister pack), into the end holes and tighten. FIGURE 3Q FIGURE 3R PAGE 19 PSM15E3R SEMI-VERTICAL - HUSSMANN...
FIGURE 3S FIGURE 3T On patch or crown end kickplates, cut the profile seal in a 45 angle in order to attach it to the bottom of the front kickplate panel. PAGE 20 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Page 21
FIGURE 3U Attach the profile seal to the bottom of the front kickplate panel. FIGURE 3T FIGURE 3V FIGURE 3S This front kickplate ajdustment bracket will be screwed onto the support assembly. PAGE 21 PAGE 21 PSM15E3R SEMI-VERTICAL - HUSSMANN...
FIGURE 3X CAUTION: Remove or protect the Top of the case expansion (TX) valve feeler bulbs (or power lead if electronic valve) from heat. Ensure the power lead is clear of heat and flame. PAGE 22 PSM15E3R SEMI-VERTICAL - HUSSMANN...
No Support 5. Ensure trap is primed before starting refrigeration. FIGURE 3Y- Drain Tap Orientation Drain waste diameter should be nominal 40mm standard AS/NZS pipe. Drain Pipe Stand/Support FIGURE 3Z Drain Tap Orientation PAGE 23 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Figure 3AC. FIGURE 3AA Ensure case earthed when proceeding with electical components. Electric shock or fire may occur if not correctly processed. Defrost Temp Probe FIGURE 3AC PAGE 24 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Page 25
Always have suitable PPE and working from heights SWMS in place. Work as far from edges as feasible. If unsafe, do not access the top of the cabinet. Air On Temp Probe FIGURE 3AE PAGE 25 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Repeat upper bracket fastening for each end of bottom of bracket towards the case upright as the mirror as shown in Figure 3AI. shown in Figure 3AG. FIGURE 3AH FIGURE 3AF FIGURE 3AI Bracket Insert Here Bracket Insert Here FIGURE 3AG PAGE 26 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Page 27
• Ensure mirror ends are correctly aligned with the case bay. • Once all these steps are done, mirror installation is complete. FIGURE 3AJ FIGURE 3AL Push Up to Install FIGURE 3AK FIGURE AM PAGE 27 PSM15E3R SEMI-VERTICAL - HUSSMANN...
» • Set expansion valves and EPRs as per Product markers, or the like on the glass. Engineering Data (Available from Hussmann). Do not use razor blades or any other mechanical » • Approximately 24 hours after start-up, check that...
This can cause the glass to shatter and includng fan motors and lights. could result in personal injury. Allow glass fronts, ends and service doors to warm before applying hot water. Do NOT use hot water inside the case. PAGE 29 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Page 30
Rinse and wipe dry immediately after cleaning. Never use hydrochloric acid (muriatic acid) on stainless steel. WEAR APPROPRIATE PPE GEAR WHILST CLEANING. PAGE 30 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Please contact Hussmann Pty Ltd or your service provider. Cases should also be cleaned by store staff on at least a weekly basis; some cases may require more frequent cleaning.
11. Carefully clean the evaporator using a soft bristle brush and mild soapy water, clean any residue with a bucket of warm water and drain out. Ensure the drain is free flowing and check it for damage. PAGE 32 PSM15E3R SEMI-VERTICAL - HUSSMANN...
FIGURE 4A WARNING: Always disconnect the electrical power at the main disconnect when servicing or replacing any electrical component. This includes, but is not limited to, such items as fans, heaters, thermostats, and lights. PAGE 33 PSM15E3R SEMI-VERTICAL - HUSSMANN...
4. Remove hinge and replace. FIGURE 4D Remove FIGURE 4B Grub Screw FIGURE 4E Remove Screw In reverse order replace hinge and door assemblies, ensuring all parts are retained in their original locations. FIGURE 4C Security Pin PAGE 34 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Dismantle the cabinet in accordance with the • Wood local laws on waste disposal and in respect of the • environment in which we live. • Polystyrene • Polycarbonate Remaining materials to be disposed of by commercial waste management. PAGE 35 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Re-do the shelf arrangement as per significantly from original specified setup. the original specification. Air return is blocked by merchandise. Move merchandise to be within the load limit. None of above. Contact your refrigeration service provider. PAGE 36 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Page 37
No power supply. Check supply is “on” and light switch is working. Light components maybe faulty or Call your refrigeration service provider operating in fail safe. to check and replace if necessary. Lamp failed. Replace lamp. PAGE 37 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Cuts and stabbing - Potential for cuts caused by Visual inspection and regular maintenance. Request damaged or missing parts service call when necessary. PPE must be worn when handling broken or damaged parts. PAGE 38 PSM15E3R SEMI-VERTICAL - HUSSMANN...
Page 39
Suffocation - Should a refrigerant leak occur there may- Ensure that the work area is well ventilated. be risks of oxygen deprivation in enclosed spaces PAGE 39 PSM15E3R SEMI-VERTICAL - HUSSMANN...
APPENDIX 3 - WARRANTY APPENDIX 4 - DISCLAIMER The information in this manual is for “Qualified Hussmann reserves the right to modify the Persons Only”. It is NOT an Installation Guide for components within the case, as well as alter “NON Qualified Persons”.