Download Print this page
CALEFFI 252169A Installation And Commissioning Manual

CALEFFI 252169A Installation And Commissioning Manual

Adjustable thermostatic mixing valve for solar systems

Advertisement

Quick Links

CALEFFI
www.cale
Adjustable Thermostatic Mixing Valve for Solar Systems
© Copyright 2018 Calef fi
INSTALLATION AND COMMISSIONING MANUAL
ASSE 1017
Scan to view
·
Installation Tip
.com
Function
The thermostatic mixer is used in solar thermal systems
producing domestic hot water. Its function is to maintain the
temperature of the mixed water supplied to the user constant at
the set value when there are variations in the supply conditions
of the incoming hot and cold water. This particular series of
mixing valves can function continuously at the high
temperatures of incoming hot water from the solar storage tank.
The valve has been speci cally certi ed to ASSE 1017.
Product range
Series 2521 thermostatic mixing valve. Union thread NPT male
connections, sizes 1/2", 3/4",1"; union solder connection, size
1/2", 3/4", 1".
Technical Characteristics
· Materials: - Body:
- Shutter:
- Springs:
- Seals:
· Setting range:
· Accuracy:
· Max working pressure (static):
· Max working pressure (dynamic):
· Min working pressure (dynamic):
· Max hot water inlet temperature:
· Maximum inlet pressure ratio (H/C or C/H):
· Minimum temperature di erence between hot water inlet and
mixed water outlet for optimum performance:
· Min. ow rate to ensure stable temperature: 1.3 gpm (5 lpm)
· Certi ed to:
· Lead Plumbing Law Compliance:
· Lead Plumbing Law Certi ed by ICC-ES, le MPG-1360.
2521 Series
(<0.25% Lead content), chrome plated
85–150°F (30–65°C)
(0.25% Max. weighted
average lead content)
28114.02
Low-lead brass
PSU
Stainless steel
EPDM
±3°F (±2°C)
200 psi (14 Bar)
75 psi (5 bar)
3 psi (0.2 bar)
212°F (100°C)
2:1
30°F (15°C)
ASSE 1017

Advertisement

loading

Summary of Contents for CALEFFI 252169A

  • Page 1 CALEFFI 28114.02 www.cale .com Adjustable Thermostatic Mixing Valve for Solar Systems 2521 Series © Copyright 2018 Calef fi INSTALLATION AND COMMISSIONING MANUAL Function The thermostatic mixer is used in solar thermal systems producing domestic hot water. Its function is to maintain the...
  • Page 2: Safety Instruction

    SAFETY INSTRUCTION This safety alert symbol will be used in this manual to draw attention to safety related instructions. When used, the safety alert symbol means ATTENTION! BECOME ALERT! YOUR SAFETY IS INVOLVED! FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN A SAFETY HAZARD. WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm.
  • Page 3 Operating Principle The controlling element of the solar thermostatic mixing valve is a temperature sensor that is fully immersed in the mixed water outlet passage. As it expands or contracts, the sensor continuously establishes the correct proportion of hot and cold water entering the valve.
  • Page 4 Exploded diagram Regulating knob Head fixing screw Regulating spindle “O” Ring seal Upper shutter seat Thermostatic element Inner shutter “O” Ring Outer shutter “O” Ring “O” Ring Spring cover Spring Valve body Union nut Gasket Tail piece body COLD...
  • Page 5: Installation

    Thermostatic mixing valves are typically installed at the outlet of hot water storage tanks in solar systems to ensure constant temperature of the mixed water supplied to the end user. Because of their ow characteristics, the valves can be installed to control the temperature for both single point of use and for point of distribution.
  • Page 6 Application Diagrams Key to symbols MAX 7 Safety relief valve HOT/RED COLD/BLUE Isolation and check valve Isolation valve Expansion vessel Filter Normally closed valve...
  • Page 7 Every 12 months at least, or more often if necessary. 1) Check and clean the system filters. 2) Verify that any check valves positioned upstream of the Caleffi valve are operating correctly, without problems caused by impurities.
  • Page 8: Troubleshooting

    Insu cient supply pressures. · Restore inlet supplies. c) Debris obstructing valve · Clean debris or scale operation. from valve. Leave this manual for the user. Caleffi North America, Inc. 3883 West Milwaukee Road Milwaukee, WI 53208 T: 414.238.2360 F: 414.238.2366 6-6-18...

This manual is also suitable for: