Warning (Gas Models Only)
!
Dryers built for use with a voltage between 200
and 240 must verify the input voltage during
installation. If the nominal voltage is outside of the
medium tolerances shown on the diagram below, adjust
the autotransformer, located near the burner assembly. To
adjust the autotransformer wiring, place the red wire on the
appropriate tap (HIGH, MED, LOW) of the autotransformer.
For additional wiring details, refer to the electrical diagram
located on the inside of the control panel.
TERM
HIGH
MED
LOW
Electrical Service Specifications
Gas and Steam Models Only
ELECTRICAL SERVICE SPECIFICATIONS
IMPORTANT:
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.
NOTES:
A.
When fuses are used they must be dual element, time delay, current
limiting, class RK1 or RK5 ONLY . Calculate/determine correct fuse
value, by applying either local and/or National Electrical Codes to
listed appliance amp draw data.
B.
Circuit breakers are thermal-magnetic (industrial) motor curve type
ONLY . For others, calculate/verify correct breaker size according to
appliance amp draw rating and type of breaker used.
C.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
WIRE
PHASE
VOLTAGE
SERVICE
120
1ø
200
1ø
208
1ø
220
1ø
230
1ø
240
1ø
120
1ø
200
1ø
208
1ø
220
1ø
240
1ø
220
1ø
230
1ø
MD G7 7
120
1ø
200
1ø
208
1ø
220
1ø
240
1ø
220
1ø
230
1ø
18
LINE VOLTAGE
50 Hz
60 Hz
260
283
226
249
239
260
208
230
217
236
189
208
APPROX.
CIRCUIT
AMP DRAW
BREAKER
60 Hz
50 Hz
MD G3 1
2
10.3
—
15
2
8.7
8.8
15
2
8.4
—
15
2
—
8.1
15
2
—
7.8
15
2
7.7
—
15
MD G5 1
2
15.6
—
20
2
10.5
—
20
2
10.5
—
20
2
10.0
—
20
2
9.7
—
20
2
—
10.7
20
2
—
10.8
20
2
15.6
—
20
2
10.5
—
20
2
10.5
—
20
2
10.0
—
20
2
9.7
—
20
2
—
10.7
20
2
—
10.8
20
29/06
Maytag Co.
113430-3