Technical Data - barbas UNIVERSAL-6 85 Installation Instructions & Manual For Annual Maintenance

Wood-burning insert appliance
Hide thumbs Also See for UNIVERSAL-6 85:
Table of Contents

Advertisement

8

TECHNICAL DATA

Combustion:
Measured in compliance with
Fuel
Nominal output
Effi ciency
Emissions
Carbon monoxide (CO)
Dust
Total hydrocarbons (C
Nitrogen oxides (NO
Flue gas mass fl ow
Flue temperature
Chimney draught
Flue gas connection
Weight
Inside:
Dimensions
- surface area (b x d)
- clear fi re opening (h x b)
Interior side panels
Interior bottom
Inner lining
Bottom retardant plate (brake plate)
Top retardant plate
Outside:
Construction
Doors
Operation:
Ash collection:
54
H
)
x
y
)
x
EN 13229 : 2001 and EN 13229 - A2 : 2004
Wood
12 kW
77%
0.10%; 1210 mg/m
3
3
20 mg/Nm
(STP, at 13% O
91 mg/m
3
(STP, at 13% O
3
105 mg/m
(STP, at 13% O
12.1 g/s
297°C
0.12 mbar
Ø180 mm (Ø178 mm ext.)
141 kg
0.120 m
2
407 x 679 mm
Heat-resistant panels 1400 kg/m
Steel (heat-resistant and rust-proof)
Steel (heat-resistant and rust-proof)
Heat-resistant panel 2000 kg/m
Stainless steel
Sheet-steel casing.
Flat door opening to left.
Shutter with fi xed handle.
• Handle for opening the door.
• Combustion air supply slider
Single combined slide for controlling the
primary, secondary and tertiary air supply.
Ashtray with grate.
UNIVERSAL-6 85
(STP, bij 13% O
)
2
)
2
)
2
)
2
3
, 1300°C
3
, 1300°C
Installation instructions

Advertisement

Table of Contents
loading