Short Timer; Cord Heater Control - Toshiba RAS-25S4KVDG-ND Service Manual

Hide thumbs Also See for RAS-25S4KVDG-ND:
Table of Contents

Advertisement

Item
In the normal condition, after switching one circuit

26. Short Timer

breaker, 3-minute delay time for compressor and
1 hour for plasma air purifier are set for the
maintenance of the unit.
ase plate cord heater control
27. Cord
B
Heater
Control
When TO sensor is defective or the air
conditioner is cooling operation, heater
output is turned off.
Operation flow and applicable data, etc.
4
3
3
TO temp.
2ºC
0 ºC
Purpose
To start the unit immediately for the purpose of
testing, trial...etc, short timer can be used.
maintenance of the unit.
Short Timer Setting
j
k
l
MODE
m
FAN
MENU
n
SWING
EXIT
FIX
FIX
1. Purpose
Heater output
2.
OFF
ON
(Equivalent to 100W)
- 50 -
Description
Press [
] button to turn the unit OFF.
Set the operation mode or plasma air
purifier on the remote control without
sending the signal to the unit.
Press
button and hold, "00" will
show on display, them press [
button to make "00" disappear.
Press [
] button to turn the unit ON.
When short timer is activated, all
setting on the remote operates
immediately, besides, all indicatiors on
front panel turns ON continuously for
3 seconds.
Base plate freeze prevention of the
outdoor unit.
Operation
As shown in the figure below, the
base plate freeze preventive
heater is controlled by temperature
of the outside temperature sensor
(TO).
]