Bosch C 950 Installation And Operation Instruction Manual page 17

Indoor model
Table of Contents

Advertisement

Description
3- In. Rain Cap
4- In. Diameter SDR-26 Pipe
3- In. Y
Concentric Fitting
2- ½ In. Diameter SDR-26 Pipe
3- In. Condensate drain Tee
1.5- In. Condensate drain bushing N/A
Table 6
PVC concentric vent part breakdown
C 950/C 1050 (Pro TL 175 C/199 C) – 6 720 805 440 (2019/10)
Length
Kit part
no. and
quantity
196016
N/A
1
24 In. long
1
N/A
1
37-1/8 in.
1
long
N/A
1
1
Fig. 9
Concentric vent kit example
[1] Exhaust
[2] Combustion air
[3] Roof boot/flashing (field supplied)
[4] Exhaust pipe
[5] Drain tee (196061, included in concentric vent kits) as
required. See chapter 4.3.2.
[6] Intake pipe
[7] Concentric vent kit (196016)
[8] Maintain 12 in. (18 in. for Canada) minimum clearance
above highest anticipated snow level maximum of 24 in.
above roof
Installation instructions
17