Pickering 40-680 User Manual

Pxi solid state multiplexer module

Advertisement

Quick Links

40-680 User Manual
PXI Solid State Multiplexer Module
pickeringtest.com
Issue 8.2 May 2023

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 40-680 and is the answer not in the manual?

Questions and answers

Summary of Contents for Pickering 40-680

  • Page 1 40-680 User Manual PXI Solid State Multiplexer Module pickeringtest.com Issue 8.2 May 2023...
  • Page 2 © COPYRIGHT (2023) PICKERING INTERFACES. ALL RIGHTS RESERVED. No part of this publication may be reproduced, transmitted, transcribed, translated or stored in any form, or by any means without the written permission of Pickering Interfaces. Technical details contained within this publication are subject to change without notice.
  • Page 3 Pickering Interfaces strives to fulfil all relevant environmental laws and regulations and reduce wastes and releases to the environment. Pickering Interfaces aims to design and operate products in a way that protects the environment and the health and safety of its employees, customers and the public. Pickering Interfaces endeavours to develop and manufacture products that can be produced, distributed, used and recycled, or disposed of, in a safe and environmentally friendly manner.
  • Page 4: Product Safety

    If this product is heavy reference should be made to the safety instructions for provisions of lifting and moving. STATIC SENSITIVE To indicate that static sensitive devices are present and handling precautions should be followed. REED RELAY MODULE 40-110/115/120/125 SOLID STATE MULTIPLEXER MODULE 40-680 Page (IV) Page (IV)
  • Page 5: Table Of Contents

    Pre Operation Checks ............3.1 Hardware Installation ............3.2 Software Installation .............3.2 Testing Operation ..............3.3 Section 4 Programming Guide ..............4.1 Programming Options For Pickering PXI Modules ....4.1 40-680 Module Architecture ..........4.2 Sub-unit Cross Reference ............4.3 Programming The 40-680 Module ........4.19 Section 5 Connector Information ..............5.1 Section 6 Trouble Shooting .................6.1...
  • Page 6 THIS PAGE INTENTIONALLY BLANK SOLID STATE MULTIPLEXER MODULE 40-680 Page (VI)
  • Page 7: Warnings And Cautions

    Not to be used in safety critical circuits, refer to the Pickering Interfaces’ terms & conditions of sale. This module must not be used for the switching of Mains Circuits. For the switching of voltages up to the module’s full specification, Secondary Circuit power supplies and the Device Under Test must...
  • Page 8 • For suitably equipped products in the event of an emergency press the red “emergency stop” button situated on the front of the unit. SOLID STATE MULTIPLEXER MODULE 40-680 Page (VIII) 2 AMP 1-POLE UHD MATRIX MODULES 40-575 / 576 / 577 / 578 / 579...
  • Page 9 Supported by PXI or LXI Chassis y Supported by eBIRST ™ y 3 Year Warranty The 40-680 is ideal for applications requiring high speed, long service life and frequent switch operation. Based on FET switches the multiplexers have no wear out mechanism and include fault protection that ensures they are automatically disconnected when PXI power is not applied.
  • Page 10 Low-voltage safety EN61010-1:2010, EMC Immunity EN61326-1:2013, +3.3 V +5 V +12 V -12 V Emissions EN55011:2009+A1:2010. 60 mA 35 mA Typical channel on resistance (Ω vertical) versus applied Voltage (horizontal) for 40-680 pickeringtest.com SOLID STATE MULTIPLEXER MODULE 40-680 Page 1.2...
  • Page 11 Pickering can supply mating 200-pin connectors and All customized products are given a unique part number, cable assemblies to enable easy integration of the 40-680 fully documented and may be ordered at any time in the series of multiplexer modules future.
  • Page 12 We provide a full range of supporting cable and connector solutions for all our switching products—20 connector families with 1200+ products. We offer everything from simple mating connectors to complex cables assemblies and terminal blocks. All assemblies are manufactured by Pickering and are guaranteed to mechanically and electrically mate to our modules. Connectors & Backshells...
  • Page 13 Solid State Multiplexer, 40-680 Programming Pickering provide kernel, IVI and VISA (NI & Keysight) drivers which are compatible with all Microsoft supported versions of Windows and popular older versions. For a list of all supporting operating systems, please see: pickeringtest.com/os The VISA driver support is provided for LabVIEW Real Time Operating Systems (Pharlap and Linux-RT).
  • Page 14 SECTION 1 - TECHNICAL SPECIFICATION pickering THIS PAGE INTENTIONALLY BLANK SOLID STATE MULTIPLEXER MODULE 40-680 Page 1.6...
  • Page 15: Functional Description

    U18, U23, U28 & U33 SOLID STATE SHIFT 8 - 1 REGISTERS SWITCHING MUX’S U13 & U14 U19, U24, U29 & U34 Figure 2.1 - Solid State Multiplexer Module (40-680): Functional Block Diagram SOLID STATE MULTIPLEXER MODULE 40-680 Page 2.1...
  • Page 16 SECTION 2 - TECHNICAL DESCRIPTION pickering THIS PAGE INTENTIONALLY BLANK SOLID STATE MULTIPLEXER MODULE 40-680 Page 2.2...
  • Page 17: Installation

    Modular products require installation in a suitable PXI/LXI chassis. The module is designed for indoor use only. PREOPERATION CHECKS (UNPACKING) 1. Check the module for transport damage and report any damage immediately to Pickering Interfaces. Do not attempt to install the product if any damage is evident.
  • Page 18: Hardware Installation

    For a system comprising more than one chassis, turn ON the last chassis in the system followed by the penultimate, etc, and finally turn ON the external controller or chassis containing the system controller. 9. For Pickering Interfaces modular LXI installation there is no requirement to use any particular power up sequence.
  • Page 19: Testing Operation

    Figure 3.2 - General Soft Front Panel Icon A selector panel will appear, listing all installed Pickering PCI, PXI or LXI switch cards and resistor cards. Click on the card you wish to control, and a graphical control panel is presented allowing operation of the card.
  • Page 20 SECTION 3 - INSTALLATION pickering THIS PAGE INTENTIONALLY BLANK SOLID STATE MULTIPLEXER MODULE 40-680 Page 3.4...
  • Page 21: Programming Guide

    SECTION 4 - PROGRAMMING GUIDE PROGRAMMING OPTIONS FOR PICKERING INTERFACES PXI MODULES For information on the installation and use of drivers and the programming of Pickering’s products in various software environments, please refer to the Software User Manual. This is available as a download from: https://www.pickeringtest.com/support/software-drivers-and-downloads...
  • Page 22: 40-680 Module Architecture

    40-680 MODULE ARCHITECTURE The 40-680 Multiplexer Module utilises an array of 20 eight-channel solid state FET switches. In the default state all switches are open circuit. Energising a particular switch appropriately creates a signal path between the common terminal and the selected channel terminal. The basic unit of 8 channels allows the following 1-pole configurations:...
  • Page 23: Sub-Unit Cross Reference

    20.3 20.4 20.5 20.6 20.7 20.8 Figure 4.1 - 40-680-001 Switching Architecture - 20-Bank, 8-Channel, 1-Pole TABLE 4.1 - Multiplexer Module 40-680-001: Sub-Units 40-680-001 Sub-Unit Cross Reference (20 Bank, 8 Channel, 1 Pole) Sub- Sub- Signal Path IVI Channel Names...
  • Page 24 SECTION 4 - PROGRAMMING GUIDE pickering TABLE 4.1 - Multiplexer Module 40-680-001: Sub-Units (Continued) 40-680-001 Sub-Unit Cross Reference (20 Bank, 8 Channel, 1 Pole) Sub- Sub- Signal Path IVI Channel Names Signal Path IVI Channel Names Unit Unit C9 to 9.1...
  • Page 25 10.3 10.4 10.5 1.16 2.16 10.16 Figure 4.2 - 40-680-002 Switching Architecture - 10-Bank, 16-Channel, 1-Pole TABLE 4.2 - Multiplexer Module 40-680-002: Sub-Units 40-680-002 Sub-Unit Cross Reference (10 Bank, 16 Channel, 1 Pole) Sub- Sub- Signal Path IVI Channel Names...
  • Page 26 SECTION 4 - PROGRAMMING GUIDE pickering TABLE 4.2 - Multiplexer Module 40-680-002: Sub-Units (Continued) 40-680-002 Sub-Unit Cross Reference (10 Bank, 16 Channel, 1 Pole) Sub- Sub- Signal Path IVI Channel Names Signal Path IVI Channel Names Unit Unit C5 to 5.1...
  • Page 27 BANK 5 1.32 2.32 3.32 4.32 5.32 Figure 4.3 - 40-680-003 Switching Architecture - 5-Bank, 32-Channel, 1-Pole TABLE 4.3 - Multiplexer Module 40-680-003: Sub-Units 40-680-003 Sub-Unit Cross Reference (5 Bank, 32 Channel, 1 Pole) Sub- Sub- Signal Path IVI Channel Names...
  • Page 28 SECTION 4 - PROGRAMMING GUIDE pickering TABLE 4.3 - Multiplexer Module 40-680-003: Sub-Units (Continued) 40-680-003 Sub-Unit Cross Reference (5 Bank, 32 Channel, 1 Pole) Sub- Sub- Signal Path IVI Channel Names Signal Path IVI Channel Names Unit Unit C3 to 3.1...
  • Page 29 BANK 3 BANK 4 1.40 2.40 3.40 4.40 Figure 4.4 - 40-680-004 Switching Architecture - 4-Bank, 40-Channel, 1-Pole TABLE 4.4 - Multiplexer Module 40-680-004: Sub-Units 40-680-004 Sub-Unit Cross Reference (4 Bank, 40 Channel, 1 Pole) Sub- Sub- Signal Path IVI Channel Names...
  • Page 30 SECTION 4 - PROGRAMMING GUIDE pickering TABLE 4.4 - Multiplexer Module 40-680-004: Sub-Units (Continued) 40-680-004 Sub-Unit Cross Reference (4 Bank, 40 Channel, 1 Pole) Sub- Sub- Signal Path IVI Channel Names Signal Path IVI Channel Names Unit Unit C2 to 2.25...
  • Page 31 SECTION 4 - PROGRAMMING GUIDE pickering BANK 1 BANK 2 1.80 2.80 Figure 4.5 - 40-680-005 Switching Architecture - 2-Bank, 80-Channel, 1-Pole TABLE 4.5 - Multiplexer Module 40-680-005: Sub-Units 40-680-005 Sub-Unit Cross Reference (2 Bank, 80 Channel, 1 Pole) Sub- Sub- Signal Path...
  • Page 32 SECTION 4 - PROGRAMMING GUIDE pickering TABLE 4.5 - Multiplexer Module 40-680-005: Sub-Units (Continued) 40-680-005 Sub-Unit Cross Reference (2 Bank, 80 Channel, 1 Pole) Sub- Sub- Signal Path IVI Channel Names Signal Path IVI Channel Names Unit Unit C1 to 1.65...
  • Page 33 SECTION 4 - PROGRAMMING GUIDE pickering BANK 1 1.160 Figure 4.6 - 40-680-006 Switching Architecture - 1-Bank, 160-Channel, 1-Pole TABLE 4.6 - Multiplexer Module 40-680-006: Sub-Units 40-680-006 Sub-Unit Cross Reference (1 Bank, 160 Channel, 1 Pole) Sub- Sub- Signal Path...
  • Page 34 SECTION 4 - PROGRAMMING GUIDE pickering TABLE 4.6 - Multiplexer Module 40-680-006: Sub-Units (Continued) 40-680-006 Sub-Unit Cross Reference (1 Bank, 160 Channel, 1 Pole) Sub- Sub- Signal Path IVI Channel Names Signal Path IVI Channel Names Unit Unit C1 to 1.65 ch65 C1 to 1.113...
  • Page 35 1-Bank, 40-Channel, 4-Pole 40.1 40.2 40.3 BANK 1 40.4 TABLE 4.7 - Multiplexer Module 40-680-404: Sub-Units 40-680-404 Sub-Unit Cross Reference (1 Bank, 40 Channel, 4 Pole) Sub- Sub- Signal Path IVI Channel Names Signal Path IVI Channel Names Unit Unit C1.1 to 1.1...
  • Page 36 SECTION 4 - PROGRAMMING GUIDE pickering TABLE 4.7 - Multiplexer Module 40-680-404: Sub-Units (Continued) 40-680-404 Sub-Unit Cross Reference (1 Bank, 40 Channel, 4 Pole) Sub- Sub- Signal Path IVI Channel Names Signal Path IVI Channel Names Unit Unit C1.1 to 17.1 C1.1 to 29.1...
  • Page 37 Switching Architecture - C1.1 1-Bank, 80-Channel, 2-Pole C1.2 80.1 80.2 TABLE 4.8 - Multiplexer Module 40-680-405: Sub-Units 40-680-405 Sub-Unit Cross Reference (1 Bank, 80 Channel, 2 Pole) Sub- Sub- Signal Path IVI Channel Names Signal Path IVI Channel Names Unit Unit C1.1 to 1.1...
  • Page 38 SECTION 4 - PROGRAMMING GUIDE pickering TABLE 4.8 - Multiplexer Module 40-680-404: Sub-Units (Continued) 40-680-405 Sub-Unit Cross Reference (1 Bank, 80 Channel, 2 Pole) Sub- Sub- Signal Path IVI Channel Names Signal Path IVI Channel Names Unit Unit C1.1 to 33.1 C1.1 to 57.1...
  • Page 39: Programming The 40-680 Module

    SECTION 4 - PROGRAMMING GUIDE pickering PROGRAMMING THE 40-680 MODULE Here are some simple examples of using the drivers with the 40-680-004 Multiplexer module. Using PILPXI To operate a solid state switch the user could use the simple OpBit command or the WriteSub commands OpBit DWORD sub_unit = 1;...
  • Page 40 SECTION 4 - PROGRAMMING GUIDE pickering THIS PAGE INTENTIONALLY BLANK SOLID STATE MULTIPLEXER MODULE 40-680 Page 4.20...
  • Page 41: Connector Information

    15.7 20.7 20.4 BANK 20 10.8 15.8 20.8 20.5 20.6 20.7 20.8 20-Bank, 8-Channel Multiplexer Figure 5.1 - Pinouts: Solid State Multiplexer Module 40-680-001 (200-pin Female LFH Connector viewed from front of module) SOLID STATE MULTIPLEXER MODULE 40-680 Page 5.1...
  • Page 42 10.3 5.14 10.14 5.15 10.15 10.4 BANK 10 5.16 10.16 10.5 10.16 10-Bank, 16-Channel Multiplexer Figure 5.2 - Pinouts: Solid State Multiplexer Module 40-680-002 (200-pin Female LFH Connector viewed from front of module) SOLID STATE MULTIPLEXER MODULE 40-680 Page 5.2...
  • Page 43: Trouble Shooting

    3.14 4.22 5.30 3.15 4.23 5.31 BANK 5 5.32 3.16 4.24 5.32 5-Bank, 32-Channel Multiplexer Figure 5.3 - Pinouts: Solid State Multiplexer Module 40-680-003 (200-pin Female LFH Connector viewed from front of module) SOLID STATE MULTIPLEXER MODULE 40-680 Page 6.3...
  • Page 44 4.38 1.39 2.39 3.39 4.39 BANK 4 2.40 3.40 4.40 1.40 4.40 4-Bank, 40-Channel Multiplexer Figure 5.4 - Pinouts: Solid State Multiplexer Module 40-680-004 (200-pin Female LFH Connector viewed from front of module) SOLID STATE MULTIPLEXER MODULE 40-680 Page 6.4...
  • Page 45 1.38 1.78 2.38 2.78 1.39 1.79 2.39 2.79 2-Bank, 80-Channel Multiplexer 1.40 1.80 2.40 2.80 Figure 5.5 - Pinouts: Solid State Multiplexer Module 40-680-005 (200-pin Female LFH Connector viewed from front of module) SOLID STATE MULTIPLEXER MODULE 40-680 Page 6.5...
  • Page 46 1.77 1.117 1.157 1.38 1.78 1.118 1.158 1.119 1.159 1.39 1.79 1.40 1.80 1.120 1.160 Figure 5.6 - Pinouts: Solid State Multiplexer Module 40-680-006 (200-pinA Female LFH Connector viewed from front of module) SOLID STATE MULTIPLEXER MODULE 40-680 Page 6.6...
  • Page 47 38.1 38.2 38.3 39.1 39.2 39.3 39.4 40.1 40.2 40.3 40.4 C1.1 C1.2 C1.3 C1.4 Figure 5.7 - Pinouts: Solid State Multiplexer Module 40-680-404 (200-pin Female LFH Connector viewed from front of module) SOLID STATE MULTIPLEXER MODULE 40-680 Page 6.7...
  • Page 48 37.1 38.1 78.1 38.2 78.2 39.1 79.1 39.2 79.2 80.2 40.1 80.1 40.2 C1.1 C1.2 Figure 5.8 - Pinouts: Solid State Multiplexer Module 40-680-405 (200-pin Female LFH Connector viewed from front of module) SOLID STATE MULTIPLEXER MODULE 40-680 Page 6.8...
  • Page 49: Maintenance Information

    PCI configuration, highlighting any potential configuration problems. Specific details of all installed Pickering switch cards are included. All the installed Pickering switch cards should be listed in the “Pilpxi information” section - if one or more cards is missing it may be possible to determine the reason by referring to the PCI configuration dump contained in the report, but interpretation of this information is far from straightforward, and the best course is to contact Pickering support: support@pickeringtest.com, if possible...
  • Page 50 SECTION 6 - TROUBLE SHOOTING pickering THIS PAGE INTENTIONALLY BLANK SOLID STATE MULTIPLEXER MODULE 40-680 Page 6.2...
  • Page 51: Relay Lookup Tables

    For PXI modules which are supported in one of Pickering Interfaces’ Modular LXI Chassis (such as the 60-102B and 60-103B) no module software update is required. If the module was introduced after the LXI chassis was manufactured the module may not be recognized, in this case the chassis firmware may need upgrading.
  • Page 52 SECTION 7 - MAINTENANCE INFORMATION pickering TABLE 7.1 - Multiplexer Module 40-680: Signal Path/Relay Look-Up Table SIGNAL PATH RELAY Path 40-680- 40-680- 40-680- 40-680- 40-680- 40-680- 40-680- 40-680- Between Pins C1 to 1.1 C1 to 1.1 C1 to 1.1 C1 to 1.1 C1 to 1.1...
  • Page 53 SECTION 7 - MAINTENANCE INFORMATION pickering TABLE 7.1 - Multiplexer Module 40-680: Signal Path/Relay Look-Up Table (Continued) SIGNAL PATH RELAY Path 40-680- 40-680- 40-680- 40-680- 40-680- 40-680- 40-680- 40-680- Between Pins C6 to 6.1 C3 to 3.9 C2 to 2.9 C2 to 2.1...
  • Page 54 SECTION 7 - MAINTENANCE INFORMATION pickering TABLE 7.1 - Multiplexer Module 40-680: Signal Path/Relay Look-Up Table (Continued) SIGNAL PATH RELAY Path 40-680- 40-680- 40-680- 40-680- 40-680- 40-680- 40-680- 40-680- Between Pins C11 to 11.1 C6 to 6.1 C3 to 3.17 C3 to 3.1...
  • Page 55 SECTION 7 - MAINTENANCE INFORMATION pickering TABLE 7.1 - Multiplexer Module 40-680: Signal Path/Relay Look-Up Table (Continued) SIGNAL PATH RELAY Path 40-680- 40-680- 40-680- 40-680- 40-680- 40-680- 40-680- 40-680- Between Pins C16 to 16.1 C8 to 8.9 C4 to 4.25 C4 to 4.1...
  • Page 56 SECTION 7 - MAINTENANCE INFORMATION pickering Figure 7.1 - Multiplexer Module 40-680: Component Layout SOLID STATE MULTIPLEXER MODULE 40-680 Page 7.6...

Table of Contents