Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0277
User Action:
Information only; no action is required
• FQXSPMA0010J: [PhysicalMemoryElementName] on Subsystem [MemoryElementName]
Throttled.
This message is for the use case when an implementation has detected Memory has been Throttled.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0142
User Action:
1. Check the XCC event log for any fan, cooling or power related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are
correctly installed in place.
3. Make sure that the room temperature is in the range in the operating specifications.
• FQXSPMA0012M: An Over-Temperature Condition has been detected on the
[PhysicalMemoryElementName] on Subsystem [MemoryElementName].
This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0146
User Action:
Complete the following steps:
1. Check the XCC event log for any fan, cooling or power related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are
correctly installed in place.
3. Make sure that the room temperature is in the range in the operating specifications.
• FQXSPMA2005I: The System [ComputerSystemElementName] has detected a POST Error
deassertion.
This message is for the use case when an implementation has detected that Post Error has deasserted.
Severity: Info
Serviceable: No
Automatically notify Support: No
56