User Manual Overview The Ossila USB powered Optical Spectrometer has been designed to simplify the optical characterisation of thin films, solutions, nanocrystals, photonic structures, and more. A compact enclosure combines with powerful electronics to deliver a fast, reliable, and cost-effective device.
Spectrometer User Manual EU Declaration of Conformity (DoC) Company Name: Ossila BV Postal Address: Biopartner 3 building, Galileiweg 8 Postcode: 2333 BD Leiden Country: The Netherlands Telephone number: +31 (0)718 081020 Email Address: info@ossila.com declare that the DoC is issued under our sole responsibility and...
Page 5
Декларация за съответствие на ЕС Производител: Ossila BV, Biopartner 3 building, Galileiweg 8, 2333 BD Leiden, NL. Декларира с цялата си отговорност, че посоченото оборудване съответства на приложимото законодателство на ЕС за хармонизиране, посочено на предходната(-ите) страница(-и) на настоящия документ.
Page 6
User Manual [Magyar] EU-s megfelelőségi nyilatkozat Gyártó: Ossila BV, Biopartner 3 building, Galileiweg 8, 2333 BD Leiden, NL. Kizárólagos felelösségünk mellett kijelentjük, hogy a felsorolt eszköz megfelel az ezen dokumentum előző oldalán/oldalain található EU-s összehangolt jogszabályok vonatkozó rendelkezéseinek. [Nederlands] EU-Conformiteitsverklaring Fabrikant: Ossila BV, Biopartner 3 building, Galileiweg 8, 2333 BD Leiden, NL.
The maximum input/output voltage of the Spectrometer’s digital pins is 5V. • Use of Equipment The Ossila Spectrometer is designed to be used as instructed. It is intended for use under the following conditions: Indoors in a laboratory environment (Pollution Degree 2).
Spectrometer User Manual Requirements The minimum computer specifications for the Ossila Spectrometer software are provided in Table 4.1. Table 4.1. Ossila Spectrometer software requirements. Operating Systems Windows 10 Dual Core 2.0 GHz 2 GB Available Hard Drive Space 300 MB...
Spectrometer User Manual Specifications The Ossila Spectrometer technical specifications are shown in Table 6.1. Table 6.1. Spectrometer specifications. Dimensions 78 mm x 78 mm x 38 mm (D x W x H) Weight 150 g Wavelength range 320 nm - 1050 nm...
II. Follow the on-screen instructions to install the software. 2. Connect the unit to your PC using the provided USB type-A to USB type-C cable. Note: The Ossila Spectroscopy software can also be downloaded from www.ossila.com/pages/software-drivers Device Overview Figure 8.1. Hardware overview.
Ossila Spectrometer Software Connecting a Device When the software starts, the user will be presented with the device connection box. Any Ossila spectrometer devices connected to the computer that are detected by the software will appear in the dropdown box.
User Manual Figure 9.2. Ossila Spectrometer software main window. Window Layout The Ossila Spectrometer software window is separated into areas indicated in Figure 9.2. The function of these areas are briefly outlined below. 9.2.1 Menu Bar Access various features related to device and software settings.
In both modes a specific axis can be controlled by using these controls on the axis labels. Measurement Modes The Ossila Spectrometer software can perform measurements in the following modes: (I) Intensity The raw output from the analogue-to-digital converter is displayed. This can take values between 0 and 65534.
(). A background and reference spectrum must be present to select this measurement mode. Trigger Modes The Ossila Spectrometer has three trigger modes that can be selected from the ‘Trigger’ dropdown box in the Measurement Settings. (I) Internal Trigger The start and end times of acquisitions are handled by the spectrometer. The time spent collecting a signal is determined by the integration time.
40 µs. With the flush disabled this delay is reduced to 15 µs. Calibration The Ossila Optical Spectrometer is factory calibrated for wavelength. Over time, it may be necessary to recalibrate the system. This can be performed by the user. The factory calibration is permanently stored in the system memory, so any user calibration can be reverted to factory calibration if required.
Next, set up the experiment. Absorption measurements require a sample to be placed in between a light source and the spectrometer. In this example we will use the Ossila Broadband White Light Source and the Ossila Spectroscopy Transmission Holder (both sold separately). However, any light source that emits over the range of the required absorption spectrum would be sufficient, and any method of fixing the sample between the light source and the spectrometer is acceptable.
Spectrometer User Manual The offset and gain values can be adjusted from within the Ossila Spectrometer Software by opening the command window from the System menu in the toolbar. The <offset?> and <gain?> commands can be used to query the current offset, and the <offset:value> and <gain:value>...
User Manual 13. Command Library The Ossila Spectrometer communicates with a host computer through a serial command library. When connected to a PC, the system will appear as a COM port, to which the serial commands could be sent. This section describes the command protocol and lists the available commands.
16. Troubleshooting The most common issues that can arise will be detailed here, however, if you encounter any issue that isn’t detailed, then please don’t hesitate to contact us by email at info@ossila.com, and we will respond as soon as possible.