intensity MINI VRF MDV-V105W/DVN1 Owner's Manual

intensity MINI VRF MDV-V105W/DVN1 Owner's Manual

Hide thumbs Also See for MINI VRF MDV-V105W/DVN1:

Advertisement

Quick Links

MINI VRF
MDV-V105W/DVN1, MDV-V120W/DVN1,
MDV-V140W/DVN1, MDV-V160W/DVN1.
Thank you very much for purchasing our air conditioner, before using your air conditioner, please read this manual carefully and keep it for future reference.
OWNER´S MANUAL
MAN-O-IVRFHR-0216
MAN-O-IMVRF-0316
intensity.mx

Advertisement

loading

Summary of Contents for intensity MINI VRF MDV-V105W/DVN1

  • Page 1 MINI VRF MDV-V105W/DVN1, MDV-V120W/DVN1, MDV-V140W/DVN1, MDV-V160W/DVN1. Thank you very much for purchasing our air conditioner, before using your air conditioner, please read this manual carefully and keep it for future reference. OWNER´S MANUAL MAN-O-IVRFHR-0216 MAN-O-IMVRF-0316 intensity.mx...
  • Page 2 Fig.1 air outlet Fix leg air inlet Refrigerant piping connection part (connection part in side) NOTE All the pictures in this manual are for explanation purpose only. They may be slightly different from the air conditioner you purchased(depend on model). The actual shape shall prevail. 16kW complying with IEC 61000-3-12.
  • Page 3: Table Of Contents

    CONTENTS PAGE It is not good for your health to expose your body to the air flow for a long time. IMPORTANT SAFETY INFORMATION............1 Do not insert fingers, rods or other objects into the air PARTS NAMES....................2 inlet or outlet. OPERATION RANGE..................3 When the fan is rotating at high speed, it will cause injury.
  • Page 4: Parts Names

    Do not touch the heat exchanger fins. 2. PARTS NAMES These fins are sharp and could result in cutting injuries. The air conditioner consists of the indoor unit, the Do not place items which might be damaged by moisture outdoor unit, the connecting pipe and the remote under the indoor unit.
  • Page 5: Operation Range

    4. OPERATION AND PERFORMANCE Th e f u n c t i o n o f t e x t r u n c i r c u l a t e a s f o w l l i n g(8/10.5/18KW . Normal display Display “--”...
  • Page 6: Malfunction Code Of Outdoor Unit

    4.5 Cooling and heating operation During operation, the fan motor in the outdoor unit may stop running under high temperature. The indoor unit of the intelligent inverter centralized air conditioner can be controlled solely, but the indoor unit in the During Fan Operation, if other Indoor Units are running on same system can not run cooling and heating at the same time.
  • Page 7 Table 5-2 (8/10.5/18kW) Malfunction or Protection Display Communication malfunction between indoor/outdoor units T3&T4 temperature sensor malfunction Power voltage protection Fan Protection Compressor discharge temperature sensor malfunction EEPROM malfunction A fan in the Aregion run for more than 5 minutes in Heat mode 2 times of E6 protection in 10 minutes Communication malfunction between IR341/main board Hi-pressure protection...
  • Page 8: Following Symptoms Are Not Air Conditioner Troubles

    6. FOLLOWING SYMPTOMS ARE NOT AIR Symptom 4.2: Indoor unit, outdoor unit CONDITIONER TROUBLES A continuous low hissing sound is heard when the system is in operation. Symptom 1: The system does not operate This is the sound of refrigerant gas flowing through both indoor and outdoor units.
  • Page 9 Table 7-1 Symptoms Causes Solution Power failure. Wait for the comeback of power. Power switch is off. Switch on the power. Fuse of power switch may have burned. ReplLocation: Unit does not start Unit does not start Batteries of remote controller exhausted Replace the batterises or check the or other problem of controller.
  • Page 10 7.2 Troubles and causes of remote controller Before asking for serving or repairing , check the following points. (see in Table 7-2) Table 7-2 Symptoms Causes Solution Check whether the MODE When the automatic mode is indicated on the display is selected, the air conditioner will "AUTO"...