Rs-485 Protocol - LG LVC-SX703PC Instruction Manual

Color video camera
Hide thumbs Also See for LVC-SX703PC:
Table of Contents

Advertisement

LVC-SX703PC_AA4HEL_ENG_MFL-129
11/7/06

RS-485 Protocol

Data Communication Format
• Data Length: 1 Byte (8 Bit)
• Start/Stop Bit: 1 BIT
• Parity Bit: None
• Baud rate: 9,600 bps
Format
BYTE 1
BYTE 2
BYTE 3
BYTE 4
BYTE 5
0xC5
CODE1
CODE2
CODE3 CAM_ID
*C.S. = Check Sum
• The data of total 6 bytes is transmitted from the
external RS-485 device to the camera.
• BYTE 6 : The value of Check Sum from 'BYTE 1 '
to 'BYTE 5 ' .
ex) In case of transmission, 0xC5, 0x5F, 0x02,
0x00, 0x0A"
C.S. = 0xC5 +0x5F +0x02 +0x00 +0x0A = 0x0130
therefore, C.S. = 0x30
38
Get other manuals https://www.bkmanuals.com
12:06 PM
Page 38
Commands
Function
Command
(external device → camera)
OSD Menu ON/OFF 0xC5, 0x5F, 0x25, 0x00, ID, C.S.
LEFT Button
0xC5, 0x5F, 0x38, 0x00, ID, C.S.
Right Button
0xC5, 0x5F, 0x39, 0x00, ID, C.S.
Up Button
0xC5, 0x5F, 0x02, 0x00, ID, C.S.
BYTE 6
Down Button
0xC5, 0x5F, 0x04, 0x00, ID, C.S.
*C.S.
Menu Button
0xC5, 0x5F, 0x24, 0x00, ID, C.S.
• You must send "Stop" command to camera after
sending each command described above.
The "Stop" command is "0xC5, 0x5F, 0x0C, 0x00,
ID, C.S.".

Advertisement

Table of Contents
loading

Table of Contents