RS-485 Protocol

Data Communication Format
• Data Length: 1 Byte (8 Bit)
• Start/Stop Bit: 1 BIT
• Parity Bit: None
• Baud rate: 9,600 bps
Format
BYTE 1
BYTE 2
BYTE 3
BYTE 4
0xC5
CODE1
CODE2
CODE3 CAM_ID
*C.S. = Check Sum
• The data of total 6 bytes is transmitted from the
external RS-485 device to the camera.
• BYTE 6 : The value of Check Sum from 'BYTE 1 '
to 'BYTE 5 ' .
ex) In case of transmission, 0xC5, 0x5F, 0x02,
0x00, 0x0A"
C.S. = 0xC5 +0x5F +0x02 +0x00 +0x0A = 0x0130
therefore, C.S. = 0x30