2. WIRING
2.2
Transceiver Unit
2.2.1
Internal wiring and cable clamp position
LAN cable
Connect with
transceiver unit.
MJ-A3SPF0018-050ZC cable
Connect with ship's mains (12-24 VDC).

Power supply

Connect the supplied power cable (MJ-A3SPF0018-050ZC, 5 m) to ship's mains (12-
24 VDC).
Note: The transceiver unit does not have a power switch.Therefore, the power cable
must be connected to the ship's mains through the switchboard. If you do not use this
equipment for a while, turn the breaker off to cut off the power to the transceiver unit.
Also, you must turn the power off or disconnect the power cable for maintenance.
2-6
P22 (TRIG-I/O)
Terminal opener
Cable securing plate
Wiring clamp
J4 (LAN)
Secure the LAN cable, using
a cable tie (supplied locally).
P20 (TD-ID)
Wiring clamp
Ground securing plate
Secure a copper strap (local supply).
MPYCSLA-4 cable
Connect with external KP signal.
P18 (TD)
Cable securing plate
Transducer cable