B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing closer than the minimums list-
ed must be constructed entirely of non-combustible materi-
als (i.e., steel studs, concrete board, etc.).
Note: Measurement is taken from top of the
opening, NOT the top of the fi replace.
Combustible or Non-Combustible Mantels
Note: All
measurements
in inches.
5
4
3
TOP OF HOOD OR FIREPLACE OPENING
Figure 10.2 Clearances To Combustibles Mantels Or Other
Combustibles
52
CEILING
12
11
10
9
8
7
6
12
11
10
9
8
7
6
5
4
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
See Dimension V on Appliance
Dimension Diagram (Figure 3.1).
Heatilator • MDV3732 Installation Manual • 2386-980 Rev. D • 11/16
Combustible Mantel Legs or Wall Projections
Figure 10.3
32
13
Non-Combustible Mantel Legs or Wall Projections
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
Figure 10.4
Note: Clearance from
opening to perpendicular wall.
5-3/8 IN.
MINIMUM
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Note: Clearance from
opening to perpendicular wall.
TOP VIEW
2-7/8 IN.
MINIMUM
FIREPLACE OPENING
Non-Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
3 IN.
MINIMUM
UNLIMITED
1/2 IN.
MINIMUM
3 FT. MAXIMUM