VLT 2800 Quick Guide
Size mm
S2
VLT 2803 - 2815
D2
VLT 2803 - 2815
VLT 2822*
VLT 2840*
PD2
VLT 2822
VLT 2840
T2
VLT 2822
VLT 2840
T4
VLT 2805 - 2815
VLT 2822 - 2840
VLT 2855 - 2875
VLT 2880 - 2882
Table 1.1: * Only 3-phase
Drill holes in accordance with the measurements given in the above table. Please note the differ-
ence in unit voltages.
Retighten all four screws.
Fit the decoupling plate to the power cables and the earth screw (terminal 95).
1.3.1 Motor coils (195N3110) and RFI 1B filter (195N3103)
NB!
With the IP 21 solution all units require a minimum of 100 mm air on each side. This
means that side-by-side mounting is NOT allowed.
A
a
B
200
191
75
200
191
75
267.5
257
90
267.5
257
140
267.5
257
140
505
490
200
267.5
257
90
267.5
257
140
200
191
75
267.5
257
90
267.5
257
140
505
490
200
MG.28.M1.02 - VLT
®
is a registered Danfoss trademark
b
C
D
E
øa
60
168
7
5
4.5
60
168
7
5
4.5
70
168
8
6
5.5
120
168
8
6
5.5
120
168
8
6
5.5
120
244
7.75
7.25
6.5
70
168
8
6
5.5
120
168
8
6
5.5
60
168
7
5
4.5
70
168
8
6
5.5
120
168
8
6
5.5
120
244
7.75
7.25
6.5
Illustration 1.1: Motor coils
1 Quick Guide
1
øb
F
øc
8
4
4.5
8
4
4.5
11
4.5
5.5
11
4.5
5.5
11
4.5
5.5
13
8
6.5
11
4.5
5.5
11
4.5
5.5
8
4
4.5
11
4.5
5.5
11
4.5
5.5
13
8
6.5
5