18
Safety and Precaution Guide for Enclosure Installation
Enclosure Design Guide
•
Design the heat dissipation system so that the panel surface temperature does not exceed 75 °C (167 °F) under
direct sunlight in the installation area.
that occur when the panel temperature exceeds 75 °C (167 °F) due to lack of Air Gap 10 mm (0.39 inches), not
applying UV protection function, and insufficient heat dissipation performance.
•
Observe the following to ensure that the panel surface temperature does not exceed 75 °C (167 °F).
Air Gap
•
Keep at least 10 mm (0.39 inches)
between the panel and the enclosure
protective glass to allow air to flow.
UV Protection
•
To prevent heat from direct sunlight, apply UV protection to the enclosure protective glass.
Spectrum (nm)
Blocking Rate
Fan Capacity
•
Select the fan capacity for sufficient heat dissipation performance. See the total fan capacity required for your model.
Display Front
(Panel ~ Enclosure Protective Glass)
Display Back
Quality assurance is not provided for failures such as yellowing and black circles
Enclosure Protective Glass
300 ~ 370
> 96 %
> 97 %
Total Fan Capacity
440 ~ 520 CFM
220 ~ 300 CFM
Air Gap
~ 380
~ 390
> 80 %
LG Open Frame
~ 400
> 60 %