Safety And Precaution Guide For Enclosure Installation - LG 49XF3E-B.AEU Owner's Manual

Table of Contents

Advertisement

Safety and Precaution Guide for Enclosure Installation

Enclosure Design Guide
Design the heat dissipation system so that the panel surface temperature does not exceed 75 degrees under direct
sunlight in the installation area.
occur when the panel temperature exceeds 75 degrees due to lack of Air Gap 10 mm, not applying UV protection
function, and insufficient heat dissipation performance.
Observe the following to ensure that the panel surface temperature does not exceed 75 degrees.
Air Gap
Keep at least 10 mm between the
panel and the enclosure protective
glass to allow air to flow.
UV Protection
To prevent heat from direct sunlight, apply UV protection to the enclosure protective glass.
Spectrum (nm)
Blocking Rate
Fan Capacity
Select the fan capacity for sufficient heat dissipation performance. See the total fan capacity required for your model.
Display Front
(Panel ~ Enclosure Protective Glass)
Display Back
Quality assurance is not provided for failures such as yellowing and black circles that
Enclosure Protective Glass
300 ~ 370
> 96 %
> 97 %
Total Fan Capacity
200 ~ 240 CFM
100 ~ 140 CFM
Air Gap
~ 380
~ 390
> 80 %
13
LG Open Frame
~ 400
> 60 %

Advertisement