COMMISSIONING
Mark the dynamic level of the closed circuit fluid in the
11.
hose on the side of the solar storage tank with a non-
permanent marker when satisfied the solar circuit
circulation is operating satisfactorily.
12.
If the procedure to check the solar circuit circulation is not
complete before the pump has automatically turned off,
then:
switch off the electrical supply at the power outlet to
the solar storage tank.
recommence this procedure from
Drain Back Function
13.
Switch off the electrical supply at the power outlet to the solar storage tank.
The red LED on the solar monitor label will stop flashing.
The pump will deactivate.
The closed circuit fluid will drain back down to the heat exchanger and the level of the closed circuit fluid
in the clear hose will rise.
Wait three (3) minutes to allow the drain back of the closed circuit fluid in the solar circuit.
Note the level of the closed circuit fluid in the fluid level hose.
14.
The closed circuit fluid should drain back to the original static level.
If the closed circuit fluid does not drain back completely to this level, then check:
there is a continuous fall of a minimum 5° (1 in 10 grade) in the solar pipe work from the solar
collectors to the solar storage tank.
the solar collectors have an inclination of not less than 10°.
"Solar Collector Location"
(refer to
the connectors on the inlet and outlet of the collectors are orientated downwards to ensure complete
drain back of the closed circuit fluid from the solar collectors.
If necessary, rectify the:
solar pipe work if there is either insufficient fall or not a continuous fall in the pipe work.
solar collector inclination if it is less than 10°.
orientation of the connectors downwards if they are not orientated correctly.
Recheck the drain back function of the solar circuit by repeating
from
step
9.
step
9.
on page 35)
54
mark dynamic
level on tank
step
7 and recommencing this procedure

Advertisement

Table of Contents
loading

This manual is also suitable for:

Premier solar ll 160lPremier solar loline