5
.
CONTROL
MODE
5
.
CONTROL
MODE
(2) Cool only appliance
a. When the room temperature exceeds 26℃, it will be ran in Cool mode,
and the temperature is set to 26℃.
b. When the room temperature exceeds 23℃, but not more than 26℃, it
will be operated in the Dry mode.
c. When the room temperature is not more than 23℃, it will be operated
in the Fan only, the air volume is set to LOW and the fan speed can be
adjusted
After the appliance start the smart operation, the setting temperature
can be adjusted 2℃(the min accuracy is
automatic temperature setting, also the presetting temperature of PCB
circuit.
In case of the specific operation selected, it could be re-select the other
modes after the compressor ceased for 5 min or the setting temperature
changed.
4.6 Super
Whether the appliance is in operation or stand-by, when the
"Super"signal is received from the remote control, it will operated at the
Cool mode and set the temperature at 18℃ and fan speed setting is High.
5. Supplementary
5.1 Time mode operation
Non-real time of Timer with remote controls can be suit for the
appliance.
5.1.1 Real time of Timer setting
(1) The max Timer ranges is 24 hours.
(2) Timer ON/OFF
(3) Timer ON/OFF can be set available in turn.
(4) The Timer accurate more than 97%
(5) The Timer can be adjusted by 1 min increase.
(6) The appliance can be set the ON-Timer and OFF-Timer in the same
time, but no any timer setting indicated.
5.1.2 Non-Real time of Timer setting
(1)The max Timer ranges is 24 hours.
(2)Timer ON/OFF
(3)Timer ON/OFF can be set available in turn.
(4)The Timer accurate more than 97%
(5)The Timer can be adjusted by 0.5 hour increase.
( 6 ) The OFF-Timer can be set when the appliance is in operation, the
ON-timer can be set when the appliance is in suspension, and the Timer
setting is display.
1℃) up and down base on the

Advertisement

Table of Contents
loading