Outing function

This function prevents the room temperature from rising too high
(or dropping too low) when no one is in the room due to outing, etc.
General Performance of the Outing Function
COOL / DRY
The air conditioner starts operation when the
room temperature increases up to –1 °C of the
upper limit.
The air conditioner stops operation when the
room temperature decreases up to –2 °C of the
upper limit.
HEAT
The air conditioner starts operation when the
room temperature increases up to +1 °C of the
lower limit.
The air conditioner stops operation when the
room temperature decreases up to +2 °C of the
lower limit.
[Precautions]
• The outing control only starts/stops the air conditioner. It does not change the
operation mode/temperature setting.
Therefore, the operation mode/temperature needs to be set beforehand so that
the outing function turns on the air conditioner with your desired operation mode/
temperature setting.
• If the room temperature rapidly changes, the room temperature may get over the
upper or lower limit when the outing function is activated.
• The outing function is invalid during FAN/AUTO operation mode.
• The air conditioner's stop order (stated in
function is operated.
If operated using other remote controller (or a central control device such as System
Controller), the outing function does not work.
• Outing function indication
Outing function
indication
Off
Flashing
Lighting
Note
z A remote controller loses outing function operation information when electrical
supply is cut for seventy two hours or more during outing function. Following power
restoration, the unit does not operate in outing function mode.
16
(EN)
The outing function is not set.
The outing function is now being set, or under operation.
Although the outing function is set, not under operation.
Outing function upper limit
Room temperature
Room temperature
Outing function lower limit
/ above) is valid only when the outing
Status
1 °C
1 °C
1 °C
1 °C