Maintenance; Periodical Check; Maintenance Procedure (Periodical Check Parts); Replacing The Separation Roller Assy - Olivetti PC-405 Service Manual

Option printer
Table of Contents

Advertisement

Field Service Ver. 1.0 Jul. 2007

Maintenance

2.

Periodical check

2.1

Maintenance procedure (Periodical check parts)

2.1.1

Replacing the separation roller assy

A. Periodically replaced parts/cycle
• Separation roller assy: Every 300,000 prints
NOTE
• Replace the separation roller assy, feed roller and pick-up roller at the same time.
B. Replacing procedure
1. Remove the right door.
See P.12
[1]
[2]
[1]
Y109030-4
[2]
[1]
A093F2C500DA
[3]
A093F2C501DA
Service Manual
2. Periodical check
2. Remove two screws [1] and remove
the separation roller mounting
bracket assy [2].
3. Remove two C-rings [1] and the
shaft [2], and remove the separation
roller fixing bracket assy [3].
NOTE
• Be careful not to lose spring at this
time.
3