Fuel Tank Cap
Turn counterclockwise to remove the fuel tank cap.

Ground Terminal

The generator's ground terminal must always be used to connect the
generator to a driven ground rod. Connect the ground terminal to the driven
ground rod with a 12 AWG (American Wire Gage) copper wire. The wire
connects to the terminal between the lock washer and nut. Tighten the nut
securely to ensure good connection. Grounding the generator protects you
from electric shock that results from a build up of static electricity or
undetected ground faults.
WARNING!
Only operate generator on a level surface.
Always connect the nut and ground terminal on the frame to an appropriate ground source.
CONTROL PANEL FUNCTIONS
Generator must be properly grounded to prevent electrocution.