Rear Panel - Inter-m EP-6216 Operation Manual

Emergency panel
Table of Contents

Advertisement

Rear Panel

Rear Panel
1. MATRIX CONNECTOR
This multi-pin EMG jack is for the connection of an external timer, such as the Inter-M ECS-6216P.
2. REMOTE MIC TERMINAL
Connect an external microphone to this terminal. The external mic is active when the Remote Mic Switch (3)
is set to External.
3. REMOTE MIC SWITCH
Connect the Remote Mic switch to this terminal.
4. DC 24V OUT TERMINAL
Automatically output when automatic announcement.
5. AUTO ANN SELECTOR SWITCH
This switch is used to set the auto announcement mode to either external or internal.
6. SIREN VOLUME
This knob controls siren level.
7. PRE-AMP INPUT JACK
This jack is used to connect the output of a pre-amplifier.
8. REMOTE 1, 2 INPUT JACKS
These jacks are used to connect the output of a pre-amplifier to REMOTE 1 and REMOTE 2.
EMERGENCY PANEL
EP-6216
5