  • Page 1 Orbital shaker-incubator ES-20/80C Operating Manual...
  • Page 2 Edition 1.03 – July of 2022 Orbital shaker-incubator ES-20/80C Page 2 Operating manual...
  • Page 3: Table Of Contents

    About this edition of user instructions 1.1. The current edition of the user instructions applies to the following models and versions: Model and name Version ES-20/80C, orbital shaker-incubator V.1GD Edition 1.03 – July of 2022 1.2. Edition 1.03 – July of 2022...
  • Page 4: Safety Precautions

    If liquid penetrates into the unit, disconnect it from the mains and have it checked by a repair and maintenance technician. • Do not operate the unit in premises where condensation can form. Operating conditions of the unit are defined in the Specifications section. Edition 1.03 – July of 2022 Orbital shaker-incubator ES-20/80C Page 4 Operating manual...
  • Page 5: General Information

    General information ES-20/80C shaker-incubator for biotechnological and pharmaceutical laboratories is a profes- sional category equipment. The typical applications include – microbial and cell culture cultivation, pro- tein expression, solubility studies, general mixing, as well as other various applications in the fields of biology and chemistry.
  • Page 6: Getting Started

    4.2. Complete set. Package contents: 4.2.1. Standard set: ES-20/80C, Orbital shaker-incubator ................1 pce. Power cable ........................1 pce. Spare fuse (inside fuse holder) ..................1 pce. Four screws and a hex driver ................... 1 set USB drive with software and software manual ..............1 pce.
  • Page 7 Remove the remaining protective sheet. Keep both sheets! 4.4.4. Maximum number of clamps or racks can be found in the table below. FC-50 FC-1000 FC-100, FC-250 SPML FC-500 TR-21/50, TR-44/15 Edition 1.03 – July of 2022 Orbital shaker-incubator ES-20/80C Operating manual Page 7...
  • Page 8: Stacking

    (fig. 3). Fix the screws tightly. 5.6. Connect the power cables to the units and to grounded mains sockets. 5.7. Maintenance. Check the screw fixation and unit stack stability once a month. Edition 1.03 – July of 2022 Orbital shaker-incubator ES-20/80C Page 8 Operating manual...
  • Page 9 Figure 3. Washers on the screw Figure 6. Stacking three Figure 4. Stacking three Figure 5. Stacking three units, top level units, base level units, middle level Edition 1.03 – July of 2022 Orbital shaker-incubator ES-20/80C Operating manual Page 9...
  • Page 10: Operation

    Press the Run Stop key. The platform will start rotating and the timer indicator will start counting the time interval. Caution! If the speed is set to zero, pressing the Run Stop key will start the timer, but the platform will not move. Edition 1.03 – July of 2022 Orbital shaker-incubator ES-20/80C Page 10 Operating manual...
  • Page 11 100% of memory is used up in approximately 1 month. 6.9. At the end of operation, set the Power switch in position O (off). Disconnect the power cable from electric circuit. Edition 1.03 – July of 2022 Orbital shaker-incubator ES-20/80C Operating manual Page 11...
  • Page 12: Specifications

    75° Not recommended Data for samples, at 37°C and 240 RPM Only with the stacking kit installed. Base side-mounted leg parts are required for third level stacking Edition 1.03 – July of 2022 Orbital shaker-incubator ES-20/80C Page 12 Operating manual...
  • Page 13: Ordering Information

    V.1GD 230 V, 50/60 Hz, no platforms 8.2. To inquire about or order the optional accessories, contact Grant or your local Grant representative. 8.2.1. Optional accessories for ES-20/80C: Model Description HSP-30/100 Platform with clamps for 30 flasks of 100 ml...
  • Page 14: Guarantee And Service

    Open the fuse holder, located near the socket (fig. 9). Check and replace with a correct fuse if necessary, see table below: Model & version Fuse ES-20/80C V.1GD (230 V) M 4 A Figure 8. Condensation tray Figure 9. Fuse holder Fuse type M - time lag Medium Edition 1.03 –...
  • Page 15: 10. Compliance

    This product does not contain any Substances of Very High Concern (SVHCs) at greater than 0.1% that have to be identified in accordance with Regulation (EC) No 1907/2006 and therefore does not have an entry in the SCIP database. Edition 1.03 – July of 2022 Orbital shaker-incubator ES-20/80C Operating manual Page 15...
  • Page 16 Representative in the European Union (Cambridge) Ltd Grant Instruments Europe B.V Shepreth Strawinskylaan 411 Cambridgeshire WTC, Tower A, 4th Floor SG8 6GB 1077 XX Amsterdam The Netherlands Tel: +44 (0) 1763 260811 Email: grant@eu.grantinstruments.com Email: salesdesk@grantinstruments.com www.grantinstruments.com Orbital shaker-incubator / ES-20/80C / 1.04...