Installing/mounting
3.1 Basic safety instructions
Incorrect material for the diaphragm in Zone 0
Risk of explosion in the hazardous area. If operated with intrinsically safe supply devices of
category "ib" or devices of the flameproof enclosure version "Ex d" and simultaneous use in
Zone 0, pressure transmitter explosion protection depends on the tightness of the diaphragm.
● Ensure that the material used for the diaphragm is suitable for the process medium. Refer
Loss of safety for devices with "flameproof enclosure" type of protection
Risk of explosion in hazardous areas. An explosion may be caused by hot gas escaping from
the flameproof enclosure if there is too little space between it and fixed parts (e.g. walls, pipes).
● Ensure that there is a minimum clearance of at least 40 mm between the flameproof joints
Vibrations in the plant
Risk of injury or damage to device.
Vibration leads to material fatigue, for example, cracks and weld seams breaks.
Hot, toxic and corrosive process media can emerge.
● Make sure that you have mounted the pressure transmitter (including accessories)
18
WARNING
to the information in the section "Technical data (Page 55)".
WARNING
and the fixed parts.
Flameproof joint
WARNING
protected against vibration.
Refer to the information on vibration resistance in the section Technical specifications
(Page 55).