5-10. Connecting To Remote 14 Receptacle RC14

*The remaining sockets are not used.
Notes
OR
803 452
Socket*
A
24 VOLTS AC
B
C
D
REMOTE
OUTPUT
OUTPUT
CONTROL
E
I
115 VOLTS AC
J
K
GND
NEUTRAL
G
OHM'S LAW
CURRENT X RESISTANCE
CURRENT = VOLTAGE
RESISTANCE = VOLTAGE
Socket Information
24 volts ac. Protected by sup-
plementary protector CB5 (see
Section 8-8).
Contact closure to A completes
24 volt ac contactor control
circuit.
Output to remote control:+10
volts dc in MIG or Stick mode;
0 to +10 volts dc in TIG mode.
Remote control circuit common.
DC input command signal: 0 to
+10 volts from min. to max. of
remote control with Voltage/
Amperage Adjust control at
max.
115 volts, 10 amperes, 60 Hz
ac. Protected by supplementary
protector CB6 (see Section
8-8).
Contact closure to I completes
115 volt ac contactor control
circuit.
Chassis common.
Circuit common for 24 and 115
volt ac circuit.
VOLTAGE =
RESISTANCE
CURRENT
OM-4420 Page 23