技術規格 型號 TRTB72LT-C 氣體種類 香港煤氣 供氣壓力 1.5 千帕 穩壓器出口壓力 1.0 千帕 氣體入口接駁 ½吋英制陽螺紋 陶瓷玻璃厚度 4 毫米 至廚檯面 55 毫米 x 746 毫米 x 440 毫米 整體尺寸 至爐面 64 毫米 x 746 毫米 x 440 毫米 (高x闊x深) 至爐架 108.5 毫米 x 746 毫米 x 440 毫米...
Page 17
Contents Important Safety Instructions ….………………………………………… P. Installation Instructions ….…………………………………………………. P. Operation Instructions ….…………………………………………………... P. Change Battery ………………………………………………………………….. P. Maintenance ….…………………………………….………………………….… P. Troubleshooting ….…………………………………….……………………..Technical Specifications ….…………………………………………...……. P. Attention! According to the Gas Safety Ordinance of Hong Kong, any gas installation works including the installation of appliances and connection tubing, must be undertaken by registered gas installers who are registered for that appropriate classes and be employed by registered gas contractors.
Important Safety Instructions The following instructions are very important to safe operation of gas appliance. Please read through them carefully. Please contact Towngas 24-hour Customer Service Hotline on 2880 6988 for enquiry and services. Installation 1. Use approved gas tubing bearing EMSD approval marking (such as: 機電工程署批准 EMSD APPROVAL GTXXXX) or other appropriate methods accepted by EMSD.
Page 19
Important Safety Instructions 23. Clean burner caps regularly to ensure smooth passage of burner flame holes. In case of cooking spillage, clean appliance properly once it cools down. 24. If abnormal noise is observed, turn off flame. Check placement of burner caps and place them correctly after appliance cools down, reignite again.
Installation Instructions Installation Position Install the appliance in a well-ventilated room but not at the location of strong wind. Keep it away from any flammable objects (such as paper, oil), sprays or pressurized containers. The appliance should be installed with a distance of more than 150mm away from surrounding combustible materials. Allow 650mm or more clearance above appliance.
Page 21
Installation Instructions Before Installation • After removing packing, make sure that the gas appliance and accessories are not damaged. In case of doubt, do not install the appliance. Contact Towngas Company for replacement. • Keep all the packing (e.g. plastic bags, cardboard, staples) away from children to avoid danger. •...
Page 22
Installation Instructions Installation Procedures Caution: The top plate material of this appliance is Glass! • In order to avoid dangerous situation arising from breakage of glass, DO NOT apply heavy weight or strong impact on glass top. • DO NOT make any scratch at the bottom side of glass, it will cause glass breakage while in use.
Page 23
Installation Instructions 6. Placement of burner caps • Insert bottom guide pin of burner caps into guide slot of burner bases. • Place the burner caps onto the burner bases without tilting. Burner cap Do not use appliance with burner caps positioned Guide pin improperly.
Operation Instructions Ignition of Burner Ensure the control knob is at the off position Press and “ ” ● Off position turn the knob in anti-clockwise direction to ignition position. Sparks are maintained for around 10 seconds for ignition. After releasing the knob, make sure the flame persists. Attention: If the appliance has not been used for a long Ignition time, the first ignition may not succeed due to trapped...
Page 25
Operation Instructions Timer Function The timer function is applicable for the left burner only. Timer Setting Procedure 1. Ignition of gas burner Press and turn control knob anti-clockwise to ignite burner. “ 0:00 ”is shown on display when timer knob is pressed. Timer mode is 2.
Change Battery Installation of Batteries • Battery box is located at the centre bottom of appliance. • Note the polarity of batteries. The appliance is not operative if the batteries are wrongly placed. Tips : Battery life is about 7 months for 2 new alkaline batteries. Life of accessory batteries may be affected by storage period of appliance.
Troubleshooting Some malfunctions can be handled by user. But if the following remedial actions are not effective, please call Towngas Customer Service Hotline at 2880 6988 . Fault Cause Remedy 1. No ignition Spark electrode is wet. Dry the electrode with dry cloth. Spark electrode has dirt.
Page 28
Troubleshooting ERROR CODE Buzzer Sound Display Burner Description Cause Remedy Left Pi x 5 times Overheat protection Overheat Operate again after (with timer) device is activated waiting for 1 minute Right Left Overheat protection Lighting-back Operate again after device is activated waiting for 1 minute (with timer) Right...
Technical Specifications Model TRTB72LT-C Gas Type Hong Kong Town Gas Gas Supply Pressure 1.5 kPa Governor Outlet Pressure 1.0 kPa ½” B.S.P (Male) Gas Inlet Connection Ceramic Glass Thickness 4 mm To Bench Top 55 mm x 746 mm x 440 mm...