5. Remove the fan from the server:
6. Position the replacement fan so that the airflow arrow on the side of the fan is
7. Position the replacement fan in the location from which you removed the failed
8. Connect the replacement fan cable to the system board.
9. Continue with "Completing the installation".

Completing the installation

This section describes how to complete the installation.

Installing the cover and bezel

Complete the following steps to install the server cover and bezel:
1. Position the internal cables so they do not interfere with the cover installation.
2. Position the cover on top of the server and slide it forward. Press down on the
Note: The fan LEDs are lit by the Light Path Diagnostics
information about the LEDs and the Light Path Diagnostics circuitry, see
the section about Light Path Diagnostics in the Hardware Maintenance
Manual and Troubleshooting Guide.
a. Disconnect the fan cable from the system board.
b. Lift the fan out of the server.
facing or pointing toward the rear of the server.
Note: Correct airflow is from the front to the rear of the server.
fan.
Attention:
Before sliding the cover forward, make sure that all the tabs on
both the front and rear of the cover engage the chassis correctly. If all the tabs
do not engage the chassis correctly, it will be very difficult to remove the cover
later.
cover latch. The cover slides forward into position. Ensure that the cover
circuitry. For more
Airflow
Chapter 2. Installing options
27