Download Print this page

Compliance With Standards - Tyco Visonic MC-302EL PG2 Installation Instructions

Two-way wireless magnetic contact device with hard-wired input

Advertisement

3. LOCAL DIAGNOSTICS TEST
Before testing, separate the base from the cover (see Fig. 3a).
A. Press the tamper switch once and release it.
B. Put back the cover to return the tamper switch to its normal (undisturbed) position, and then secure the front cover to the base with
the case closure screw.
C. Momentarily open the door or window and verify the red LED blinks, indicating detection.
D. After 2 seconds the LED blinks 3 times.
The following table indicates received signal strength indication.
LED response
Green LED blinks
Orange LED blinks
Red LED blinks
No blinks
IMPORTANT! Reliable reception must be assured. Therefore, "poor" signal strength is not acceptable. If you receive a "poor" signal from
the device, re-locate it and re-test until a "good" or "strong" signal strength is received.
Note: For detailed Diagnostics Test instructions refer to the control panel Installer Guide.
4. MISCELLANEOUS COMMENTS
Visonic Ltd. wireless systems are very reliable and are tested to high standards. However, due to low transmitting power and limited
range (required by FCC and other regulatory authorities), there are some limitations to be considered:
A. Receivers may be blocked by radio signals occurring on or near their operating frequencies, regardless of the digital code used.
B. A receiver responds only to one transmitted signal at a time.
C. Wireless devices should be tested regularly to determine whether there are sources of interference and to protect against faults.
The user is cautioned that changes or modifications to the unit, not expressly approved by Visonic Ltd., could void the user's
FCC or other authority to operate the equipment.
The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio and television reception. However, there is no guarantee that interference will not occur in a
particular installation. If this device does cause such interference, which can be verified by turning the device off and on, the user is
encouraged to eliminate the interference by one or more of the following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit different from the one which supplies power to the receiver.
Consult the dealer or an experienced radio/TV technician

5. COMPLIANCE WITH STANDARDS

Compliance with Standards
D-304537 MC-302EL PG2 Installation Instructions
Reception
Strong
Good
Poor
No communication
Europe: EN 301 489-3, EN 50130-4:( 95) & A1 : (98) & A2: (03), EN 300 220-2, EN 60950-1,
EN 50130-5, EN 50131-1, EN 50131-6, , EN 50131-2-6: 2008.
The MC-302EL PG2 is compatible with the RTTE requirements - Directive 1999/5/EC of the European
Parliament and of the Council of 9 March 1999 and EN50131-1 Grade 2 Class II.
EN 50131-2-6, EN 50131-6, EN 50131-5-3, EN 50130-4, and EN 50130-5.
UK: This product is suitable for use in systems installed to conform to PD6662:2010 at Grade 2 and
environmental class 2. DD243 and BS8243
USA: CFR 47 part 15 (FCC)
Canada: RSS 210
This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
This device complies with the essential requirements and provisions of Directive 1999/5/EC of the
European Parliament and of the Council of 9 March 1999 on radio and telecommunications
terminal equipment.
The Power G peripheral devices have two- way communication functionality, providing additional benefits as described in
the technical brochure. This functionality has not been tested to comply with the respective technical requirements and
should therefore be considered outside the scope of the product's certification.
Wood
Opening
Closing
20mm+/-
14mm+/-
5mm
6mm
14mm+/-
15mm+/-
5mm
5mm
25mm+/-
24mm+/-
5mm
5mm
Support
Soft Iron
s
Direction
Opening
Closing
X
15mm+/-
14mm+/-
5mm
5mm
Y
15mm+/-
14mm+/-
5mm
5mm
Z
25mm+/-
24mm+/-
5mm
5mm
3

Advertisement