2.2 Positioning control by multi-step point setting

2.2.1
Settings of main parameters
When A510=1, input of the target position by multi-step point setting is enabled.
To switch points, use preset speed commands 1 to 3 (digital input terminal functions 10/11, 12/13, 14, 15).
The following are parameters necessary for positioning control by multi-step point setting.
• Set A510=1.
• Set A544 to A596 according to the number of steps of the positioning point.
For each multi-step point, the target position (example: A544, A545), frequency at the time of position control
(example: Sr1), acceleration/deceleration time until the frequency with a position command is reached
(example: A547, A548), function (example: A546) can be set with parameters. For the parameter corresponding
to each point, see the table below. For how to set, refer to 2.2.1.1 and 2.2.1.2.
Target position
Multi-step
Higher 4
point
digits
1
A544
2
A552
3
A560
4
A568
5
A576
6
A584
Function
0: Digital input
1: Pulse train input
select
2: PG input
0: Digital input
1: Pulse train input
select
2: PG input
Speed control
Set the gain of speed control.
response 1
Set the acceleration/deceleration
Acc/Dec time 1
time at the time of normal operation.
voltage 1
Motor rated
Set the motor constant by referring to
capacity
the motor nameplate.
Motor rated
current
2
Function
Lower 4
setting
digits
A545
A546
A553
A554
A561
A562
A569
A570
A577
A578
A585
A586
Setting
Speed at
Acceler-
the time of
ation
position
time
control
Sr1
A547
Sr2
A555
Sr3
A563
Sr4
A571
Sr5
A579
Sr6
A587
5
Remarks
• Set F146 and F147=2 to input the
speed feedback signal to the S4 and
S5 terminals.
• Set the relevant parameter to 1 to
input the position command signal
to S4 or S5 terminal.
Generally, set a value approx.
between 3 Hz to 5 Hz.
Auto-tuning is performed immediately
after operation start.