Toshiba TOSVERT VF-AS3 Manual page 18

Hide thumbs Also See for TOSVERT VF-AS3:
Table of Contents

Advertisement

Title
Function
Current position clearing
A527
0 point recovery select
A528
0 point offset upper 3-digit
A529
0 point offset lower 4-digit
A530
0 point creep frequency
Positioning control by pulse train input
F146
Terminal S4 input select
F147
Terminal S5 input select
PTI position clear signal
A537
select
A538
PTI position frequency UL
Positioning control by multi-step point
Position reference upper
A544
4-digits 1
Position reference lower
A545
4-digits 1
Position control function set
A546
1
Position reference increase
A547
time 1
Position reference decrease
A548
time 1
Position reference upper
A552
4-digits 2
Position reference lower
A553
4-digits 2
Position control function set
A554
2
Position reference increase
A555
time 2
Adjustment range
0: 0 point ignore (+)
1: 0 point signal (+)
2: 0 point dog system (+)
10: 0 point ignore (-)
11: 0 point signal (-)
12: 0 point dog system (-)
0 – 999
0 – 9999
0.1 – 10.0
0: Digital input
1: Pulse train input
2: PG input
0: Digital input
1: Pulse train input
2: PG input
0: Clear at the rising edge (OFF->ON)
1: Clear during ON
LL - UL (Hz)
0 – 9999
0 – 9999
0: Absolute position command, positive direction
1: Absolute position command, negative direction
2: Relative position command, positive direction
3: Relative position command, negative direction
0.00 - 600.00 (s)
0.00 - 600.00 (s)
0 – 9999
0 – 9999
0: Absolute position command, positive direction
1: Absolute position command, negative direction
2: Relative position command, positive direction
3: Relative position command, negative direction
0.00 - 600.00 (s)
16
E6582187
Default setting
value
0
0
0
0.5
0
0
1
50.0/60.0
*1
0
0
0
1.00
1.00
0
0
0
1.00