AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND. In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
NORTH AMERICAN REQUIREMENTS • This appliance must be installed in locations where it can be overseen by trained personnel. • For proper operation, this appliance must be installed where the temperature is between 41°F to 95°F (5°C to 35°C). • Appliance shall not be tilted more than 10° for safe operation. •...
ELECTRICAL REQUIREMENTS WARNING - The dispenser must be disconnected from the power source until specified in Initial Set-Up. Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements. POWER CORD POWER CORD POWER CORD NEUTRAL WHITE N BLUE NEUTRAL BLUE...
½˝ water supply line. At least 18 inches of an FDA approved flexible beverage tubing, such as reinforced braided polyethylene or silicone, before the dispenser will facilitate movement to clean the countertop. Bunn- O-Matic does not recommend the use of a saddle valve to install the dispenser. The size and shape of the hole made in the supply line by this type of device may restrict water flow.
No wait is needed, the faucet is ready to dispense another cup of hot water. NOTE - Due to the tank capacity and heater size, this product should be used only for dispensing a few cups of hot water at a time. (Larger capacity Bunn-O-Matic hot water dispensers are available.)
NOTE: The dispenser should be at operating temperature before setting dispense volumes. 1. Press and hold the hidden programming button (c) located under the ® next to the BUNN logo on the front of the dispenser until the 3 LED's begin flashing from the left to the right. Release the button.
PROGRAMMING - H5-E, H5-PC, H5X , H10X ® When power is applied to the dispenser, the display located on the bottom of the main circuit board will show the software version for 5 seconds, and then it will show the model number (see chart below) it will then go to (-).
Page 11
PROGRAMMING - H5-E, H5-PC, H5X , H10X Continued ® LEVEL 2 PROGRAMMING H1 - DISPENSE TEMPERATURE LOCKOUT - PORTION CONTROL ONLY (WILL NOT DISPLAY ON OTHER MODELS) 1. To enter Level 2 Programming, press and hold the center button until H1 appears on the display (approximately 6 seconds) then release button.
4. Install top cover, connect dispenser to power TEMP source. ENERGY SAVER MODE WARNING HOT WATER HOT WATER Step backward Programming the dispenser: 1. Press and hold upper hidden button (bottom center of “BUNN” logo) until “P1” is displayed. Continued...
Page 13
PROGRAMMING - H5 ELEMENT Continued ® 2. The display will now show the model number. (H5H) 5 Gallon High Voltage Unit (200-240V) (H5L) 5 Gallon Low Voltage Unit (100-120V) Now scroll with the (+/-) buttons through the models listed above until the display matches the model you are working with.
Page 14
PROGRAMMING - H5-ELEMENT Continued ® LEVEL 2 PROGRAMMING H2 - F° OR C° SELECTION 1. To enter Level 2 Programming, press and hold the upper hidden button until H2 appears on the display. Release the upper hidden button. The display will show either FAH (Degrees in Fahrenheit) or CEn (Degrees in Centigrade).
PROGRAMMING - H3E ELEMENT ® Program lockout switch: The switch must be in the “SET” position in order to access the program modes. 1. Disconnect the dispenser from the power source. 2. Remove the 4-40 screws and the top cover. 3.
Page 16
PROGRAMMING - H3E ELEMENT Continued ® For H3E software versions prior to 2.17 1. Press and release the hidden button. The display will show P1. Display will now show the “SET” temperature. Press the (+) button to increase the temperature set point, or the (-) button to decrease the set point.
Page 17
PROGRAMMING - H3E ELEMENT Continued ® LEVEL 2 PROGRAMMING H1 - DISPENSE LOCKOUT 1. To enter Level 2 Programming, press and hold the hidden button until H1 appears on the display. Release the hidden button. The display will show “noL” (no lockout) or Loc (dispense lockout).
Page 18
PROGRAMMING - H3E/X ELEMENT Continued ® For H3E models - S.W. 2.17 and above For H3X models - S.W. 5.11 and above P1: Model selection. H5H, H5L, H3 toggle through model numbers with +/-. NOTE: Not used on H3E models. P2: Press and release the hidden button.
Page 19
PROGRAMMING - H3E ELEMENT Continued ® P6: Press and release the upper hidden button once more. The display will read P6. This is the time delay from the last refill to the activation of energy save mode. Range: 4 hours to 24 hours. Press and release the upper hidden button once more.
CLEANING The use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic equipment. WALL MOUNTED INSTALLATION - 5 GALLON MODELS ONLY If the dispenser is wall mounted, the bottom of the dispenser should be at the same height as a counter or table top.