19.5 Installation in a tall unit
Observe the installation dimensions and the safety
clearances in a tall unit.
¡ Ensure that the intermediate floor has a gap to the
installation wall in order to ventilate the appliance.
¡ If the tall unit has another back panel in addition to
the element back panels, this must be removed.
¡ Only fit the appliance up to a height which allows
accessories to be easily removed.
Appliance connected loads
You can select a different connection depending on the appliance model. In this case, you must connect the appli-
ance on the rear of the appliance using the power cord in accordance with the connection diagram.
Ensure that the power cord corresponds to H05VV-F or higher. Determine which wire cross section you require in ac-
cordance with the current load. If required, install copper bridges. Incorrect connections may damage the appliance.
Appliance connected load
3.3 kW
4.2 kW
19.8 Installing the appliance
Slide the appliance and centre it.
1.
Do not kink the connection cable.
Open the oven door completely.
2.
52
19.6 Installing two appliances on top of
each other
Your appliance can also be installed above another ap-
pliance.
19.7 Electrical connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
¡ The fuse protection must correspond to the power
¡ The appliance corresponds to protection class I and
¡ The appliance must be disconnected from the
¡ Contact protection must be ensured by the installa-
¡ Only a licensed professional may connect appli-
Electrically connecting an appliance without a
protective contact plug
Note: Only licensed specialists may connect the appli-
ance. Damage caused by incorrect connection is not
covered under the warranty.
An isolating switch must be integrated into the perman-
ent electrical installation according to the installation
regulations.
1.
2.
3.
Min. fuse protection at 1~
16 A
20 A
rating specified on the appliance's rating plate and
to local regulations.
must only be operated with a protective earth con-
nection.
power supply whenever installation work is being
carried out.
tion.
ances without plugs. They are subject to the require-
ments of the local electricity provider.
Identify the phase and neutral conductors in the
socket.
The appliance may be damaged if it is not connec-
ted correctly.
Only connect the appliance to a mains voltage
between 220 und 240 V.
Connect the wires of the mains power cable accord-
ing to the colour coding:
Green/yellow = Conductor
Blue = Neutral conductor
Brown = Phase (external conductor)
Min. fuse protection at 2/3 N~
12 A