Furnace Control Programming; And Navigation - Bryant 926TC Installation, Start-Up, Operating And Service And Maintenance Instructions

Two-stage, non-communicating, variable 25-speed, ecm multipoise, condensing gas furnace with intelisense
Table of Contents

Advertisement

926TC: Installation, Start-up, Operating and Service and Maintenance Instructions
Airflow
Unit Size
Setting
1
2
3
4
5
6
7
8
9
10
11
12
66120V24
13
14
15
16
17
18
19
20
21
22
23
24
25
NOTE:
1. A filter is required for each return-air inlet. Airflow performance included 3/4-in. (19 mm) washable filter media such as contained in a factory - authorized accessory filter rack. See
accessory list. To determine airflow performance without this filter, assume an additional 0.1 in. w.c. available external static pressure.
2. Adjust the blower airflow setting as necessary for the proper air temperature rise for each installation.
3. Airflows over 1800 CFM require bottom return, two-side return, or bottom and side return. A minimum filter size of 20" x 25" (508 x 635 mm) is required.
4. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return
5. The - entry indicates unstable operating conditions
Unit Size
High Heating
30040V14
14
36040V17
9
36060V14
18
48060V17
10
48080V17
16
60080V21
10
60100V21
15
66100V21
13
66120V24
22
*. Setting #1 is the default setting for constant fan.

FURNACE CONTROL PROGRAMMING

AND NAVIGATION

On-Board Control Method
CAUTION
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury, or death.
Blower access door switch removes 115-V power to control. No
component operation can occur unless switch is closed. Caution must
be taken when manually closing this switch for service purposes.
Do not tape or permanently allow the door switch to be bypassed.
Temporarily depress the door switch with one hand while accessing the
service buttons with your other hand. Do not touch uninsulated
electrical components.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Table 19 – Air Delivery - CFM (with filter) (Continued)
Default
Setting
0.1
0.2
Cont. Fan
585
475
650
550
705
615
775
690
875
790
970
885
1055
975
1130
1060
1205
1130
1225
1155
1315
1250
1400
1340
1500
1440
1590
1535
Low Heating
1610
1555
1645
1590
Low Cooling
1740
1690
1785
1735
1880
1830
1970
1920
2090
2045
High Heating
2055
2005
2180
2140
High Cooling
2270
2230
2360
2305
Table 20 – Default Airflow Settings
Default Airflow Settings
Low Heating
High Cooling
8
4
9
5
10
6
10
6
15
External Static Pressure (in. w.c.)
0.3
0.4
0.5
360
265
165
440
340
250
510
410
320
600
500
410
710
625
535
815
735
655
905
835
765
990
925
855
1065
1005
940
1090
1030
965
1185
1130
1070
1280
1220
1165
1380
1325
1275
1480
1425
1375
1500
1445
1395
1540
1485
1435
1635
1585
1535
1685
1635
1585
1785
1735
1690
1875
1830
1785
2000
1955
1915
1960
1915
1870
2095
2055
2015
2185
2145
2100
2245
2185
2130
*
Low Cooling
High Heating
25
18
24
13
25
15
25
13
24
14
25
14
23
14
22
11
24
17
This furnace model is equipped with an on-board 3 digit LCD display
with pushbutton navigation for the adjustment of operating parameters,
diagnostics, and service. The control board must be powered to use the
display and pushbuttons. Upon startup, the control will alternate
displaying the Model Program Number (PRG) and Software Version
(uEr). The control board has been programmed at the factory with a
Model Program Number specific to the furnace product number. The
correct Model Program Number is shown on the furnace rating plate.
The system's status is displayed after startup or after no control buttons
have been pressed for 60 seconds. Status Code LED will also be
illuminated or blinking when displaying the system status. The codes
which indicate the current operating mode of the system as shown in
Table
21.
53
0.6
0.7
0.8
-
-
-
155
-
-
240
150
-
335
255
175
455
380
310
575
500
425
685
610
545
785
710
640
875
805
735
900
835
765
1010
950
885
1110
1050
990
1220
1170
1115
1325
1275
1225
1345
1295
1245
1385
1335
1290
1485
1440
1395
1540
1495
1445
1645
1600
1555
1740
1700
1655
1870
1830
1785
1820
1780
1735
1970
1930
1890
2060
2005
1945
2070
2005
1945
Designated Airflow Settings
Low Heating
(10 - 18)
(5 - 10)
(5 - 12)
(3 - 7)
(12 - 23)
(6 - 11)
(6 - 13)
(3 - 8)
(12 - 19)
(6 - 12)
(6 - 13)
(3 - 9)
(10 - 19)
(5 - 12)
(9 - 17)
(3 - 11)
(16 - 23)
(10 - 16)
0.9
1.0
-
-
-
-
-
-
-
-
235
155
360
290
470
410
570
510
670
605
700
640
820
755
930
870
1055
1000
1175
1120
1195
1140
1240
1190
1345
1300
1400
1355
1510
1470
1615
1570
1745
1705
1695
1655
1850
1810
1885
1825
1885
1825
Const. Fan
(1 - 3)
(1 - 5)
(1 - 3)
(1 - 8)
(1 - 5)
(1 - 8)
(1 - 3)
(1 - 9)
(1 - 3)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents