Echoback Test - Omron ZEN-8E Communications Manual

Programmable relay
Table of Contents

Advertisement

● Response Code

■ Echoback Test

● Test Data
Normal Completion
Response
Name
code
0000
Normal completion
Error Occurred
Response
Name
code
1001
Command too long
1002
Command too short
1100
Parameter error
2203
Operation error
This service performs an echoback test.
Service Request PDU
MRC SRC
Test data
0
8 0 1
2
2
Service Response PDU
Response
MRC SRC
code
0
8 0 1
2
2
4
Set between 0 and 19 bytes of user-defined test data.
Set a value for the test data within the ranges shown below according to
the communications data length.
Communications
data length
8 bits
ASCII data: H'20 to H'7E or H'A1 to H'FE
7 bits
ASCII data: H'20 to H'7E
Do not set the value H'40. No response will be returned.
2.3 Detailed Description of the Services
Description
No errors were found.
Description
The command is too long.
The command is too short.
The write data is out of the setting
range.
Unit error (Memory error occurred,
or unused command was sent.)
0 to 19
Test data
0 to 19
Test Data
31