Start day
Always 00.
2
1
24
Minutes
Example
[STX]010000102C5000000001005623592359
0 0
5
6
2 3
3. Pulse Operation
End day
Start time, hour
+
+
1
2
The time data is as follows (BCD):
Time data
Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
No day designated
Start time, hour
Start time, minutes
Output time, minutes
Output time, seconds
00 to 59
5 9
2 3
5 9
+
Start time, minutes
+
Output time,
minutes
2
2
BCD
0
1
2
3
4
5
6
7
00 to 23
00 to 59
00 to 99
00 to 59
End time: 59 minutes
End time: 23 hours
Start time: 59 minutes
Start time: 23 hours
End day: Saturday (6)
Start day: Friday (5)
Always 00.
+
Output time,
seconds