Advertisement
AN-179 | |
Power source | 220-240 V~50 Hz |
Max. charge | 2500 W R |
Frequency | Z-Wave (868.42 MHz) |
Range | up to 30 m |
Power consumption | < 1 W (standby) |
IP rating | Indoor use |
Dimensions (W x H x D) | 43 x 42 x 16 mm |
Built-in receiver for permanent installation. Small, compact size for placing in a junction box or switchbox. Can be connected to existing switch. The receiver needs both phase and neutral. The receiver is fully compatible with the Z-Wave Plus standard.
Make sure that the conductors are powered down by turning off the power in the distribution box.
Connect Phase to L and IN, Load/Ignition wire to LS and Zero Conductor to N.
AN-179 can be connected to power switches, even momentary switches, for control, also see wiring diagram.
Please note that switches connected to AN-179 must be potential free, i.e. fully insulated from 230 V.
When AN-179 is powered up for the first time and a NODE ID has not been assigned, it starts in auto-inclusion mode.
Control using Z-Wave controller: Consult the manual for your Z-Wave controller for information about how to control your receiver.
LOAD | MAX POWER |
Incandescent bulbs % Resistive loads (230 V) | 2500W /220-240 V |
Halogen lights (230 V) | 1200W / 220-240 V |
LED & Low energy bulbs (230 V) | 320 W / 220-240 V (40 W x 8) |
Read through the entire instruction first. Engage a professional if so required. Nexa cannot be held liable if the product is used for any purpose other than the one for which it is designed, or if there is failure to comply with the instruction.
Never connect bulbs or equipment exceeding the receiver's maximum stated load – this may lead to faults, short-circuiting or fire. Do not attempt to repair the product.
The product contains no repairable parts.
Range indoors:
up to 30 m (optimal conditions). The range is very dependent on the local conditions, for example, if there are metals in the vicinity. For example, the thin metal coating in energy glass with low emissivity has a negative influence on the range of the radio signals. There may be restrictions on the use of the unit outside the EU. If appropriate, you should check that the unit complies with local regulations.
Max load:
Never connect lights or equipment that exceed the receiver's maximum load. This could lead to faults, shortcircuiting or fire.
Life-support equipment:
Never use Nexa's products with lifesupport equipment or other devices where faults or interference could have life-threatening consequences.
Interference:
All wireless units can suffer from interference that can affect the performance and range. For this reason, the minimum distance between two receivers should be at least 50 cm
Repair:
Do not attempt to repair the product. It does not contain any repairable parts.
Waterproofing:
The product is not waterproof. Make sure it is dry at all times. Damp causes the electronics inside to corrode and this could lead to short-circuiting, faults and a risk for electric shocks.
Cleaning:
Clean the product with a dry cloth. Do not use chemicals, solvents or strong cleaning agents.
Environment:
Do not expose the product to intense heat or cold, because it could damage or shorten the service life of the electric circuits.
Role Type | Node Typer | Installer Icon | User Icon |
Slave Always On | Z-Wave Plus node | On/Off Power Switch | On/Off Power Switch |
Protocol Library | 3 (Slave_Enhance_232_Library |
Protocol Version | 3.95 (6.51.02) |
Group | Profile | Command Class & Command (List) N bytes | Group Name (UTF-8) |
1 | General: NA | Binary Switch Report, Notification Report, Device Reset Locally Notification | Lifeline |
2 | Control: Key1 | Basic Set | On/Off control Button 1 |
The device will send notifications (Notification Type =0x08, Event = 0x01) upon being powered on.
The configurable values are as following:
Basic Set Command Value
Parameter Number | Size | Range | Default |
1 | 2 | 0-99, 255 (0xFF) | 255 (0xFF) |
The delaying time to report to Group 1
Parameter Number | Size | Range | Default |
2 | 1 | 3-25 (seconds) | 3 |
Remember the last status:
Parameter Number | Size | Range | Default |
3 | 1 | 1/0 | 1:remember(0: do not remember) |
Switch 1 type:
Parameter Number | Size | Range | Default |
4 | 1 | 1/0 | 0: Bistable switch 1: Momentary switch |
The module supports Command Classes including • COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Need help?
Do you have a question about the AN-179 and is the answer not in the manual?
Questions and answers