Data Format Required, Drop Prefix/Suffix
Scanned data is modified according to your data format. If a data format is found for a particular symbol, those prefixes and
suffixes are not transmitted. Any data that does not match your data format requirements generates an error tone. If you
wish to process this type of bar code without generating an error tone, see
Choose one of the following options. Default = Data Formatter On, Not Required, Keep Prefix/Suffix.
* Data Formatter On,
Not Required,
Keep Prefix/Suffix
Data Format Required,
Keep Prefix/Suffix
Data Format Non-Match Error Tone
When a bar code is encountered that doesn't match your required data format, the scanner normally generates an error
tone. However, you may want to continue scanning bar codes without hearing the error tone. If you scan the Data Format
Non-Match Error Tone Off bar code, data that doesn't conform to your data format is not transmitted, and no error tone will
sound. If you wish to hear the error tone when a non-matching bar code is found, scan the Data Format Non-Match Error
Tone On bar code. Default = Data Format Non-Match Error Tone On.
* Data Format Non-Match Error
Tone On
Data Format Non-Match Error
Data Formatter On,
Not Required,
Drop Prefix/Suffix
Data Format Required,
Drop Prefix/Suffix
Data Format Non-Match
Error Tone Off
Tone.